Case

Adult cardiac arrest

ReviewSource-checked against AHA 2025; not yet independently physician-reviewed.

Adult cardiac arrest resuscitation from first principles, aligned with the 2025 American Heart Association adult basic life support, advanced life support, and post-cardiac arrest care guidelines. This is study material. Care follows the current guideline and local protocol.

Principle

Orientation and first actions

This text explains why each step of adult cardiac arrest care works, and where the explanation stops.

The management overview below lists the treatment steps in order; each links to the part that explains it.

Each part moves from mechanism to what can be observed at the bedside to what to do, and ends with its limits. Questions at the end of a part are optional and collapsed.

Abbreviations. CPR, cardiopulmonary resuscitation; ROSC, return of spontaneous circulation; VF, ventricular fibrillation; pVT, pulseless ventricular tachycardia; PEA, pulseless electrical activity; ECG, electrocardiogram; EEG, electroencephalography; ICU, intensive care unit; COPD, chronic obstructive pulmonary disease; PEEP, positive end-expiratory pressure; EMS, emergency medical services; IV, intravenous; IO, intraosseous; CT, computed tomography; ECLS, extracorporeal life support; RV, right ventricular; ESC, European Society of Cardiology. Guideline recommendations carry the American Heart Association's Class of Recommendation (COR) and Level of Evidence (LOE).

Principle

What normal circulation accomplishes26,25

Pressure, flow, and oxygen delivery are three different quantities, and a resuscitation can improve one while the others stay flat.

Oxygen enters the blood in the pulmonary capillaries, where it diffuses from the alveolar gas across a thin membrane into plasma and then into red cells. Arterial blood leaving the left heart carries it in two forms. Most is bound to hemoglobin inside the red cells; a small amount is dissolved in the plasma. Three bedside numbers describe this, and they measure different things. PaO2, the arterial partial pressure of oxygen in mm Hg, is a pressure: it reflects the dissolved oxygen, drives diffusion, and determines how fully hemoglobin is loaded, but it is not itself an amount of oxygen. SaO2 is the fraction of hemoglobin binding sites that carry oxygen, measured or calculated from an arterial sample; SpO2 is the pulse oximeter's estimate of the same fraction. Hemoglobin concentration, in g/dL, is how much carrier is present. None of the three alone says how much oxygen the blood holds. That amount is the arterial oxygen content, CaO2, in mL of oxygen per dL of blood. Content is mostly hemoglobin-bound oxygen: CaO2 ≈ (1.34 × Hb × SaO2) + (0.003 × PaO2), with hemoglobin in g/dL and PaO2 in mm Hg. Here 1.34 is the mL of oxygen carried by each gram of fully saturated hemoglobin, SaO2 is written as a fraction, and 0.003 is the mL of oxygen dissolved in each dL of blood per mm Hg of PaO2. The dissolved term is small at ordinary PaO2, which is why saturation and hemoglobin dominate content and why raising PaO2 far above the level that saturates hemoglobin adds little.

CaO2 ≈ (1.34 × Hb × SaO2) + (0.003 × PaO2)

Content describes the blood, not the patient: it says nothing about how much of that blood is moving. Oxygen delivery is the product of cardiac output and arterial oxygen content (DO2 = CO × CaO2).

DO2 = CO × CaO2

Because cardiac output is in L/min and content is in mL per dL, the product needs a factor of 10, the number of deciliters in a liter: DO2 in mL O2 per minute equals CO in L/min times CaO2 in mL/dL times 10.

During CPR the first factor is the limiting one. Cardiac output generated by compressions is a fraction of normal, so even fully saturated blood delivers far less oxygen than the tissues need. Two predictions follow. Improving compressions raises delivery more than adding oxygen to already saturated blood does. And in an asphyxial arrest, where content collapsed before flow stopped, restoring content matters as much as restoring flow, because flow without oxygen delivers nothing. An illustrative calculation, using textbook values rather than patient data or targets, shows the scale. With hemoglobin 15 g/dL, SaO2 1.00, and PaO2 100 mm Hg, bound oxygen is 1.34 × 15 × 1.00 = 20.1 mL/dL and dissolved oxygen is 0.003 × 100 = 0.3 mL/dL, so CaO2 is 20.4 mL/dL, or 204 mL per liter. At a cardiac output of 5 L/min, delivery is 5 × 20.4 × 10 = 1020 mL O2 per minute. In the same illustrative terms, cutting cardiac output to 1.5 L/min at the same content gives 1.5 × 20.4 × 10 = 306 mL per minute, while raising PaO2 to 500 mm Hg at that low flow adds only 1.2 mL/dL of dissolved oxygen, for 324 mL per minute. These are arithmetic, not measurements made during CPR, and they do not show that any intervention improves outcome.

Oxygen delivery needs content and flowThree calculated oxygen-delivery bars: at hemoglobin 15 g/dL and saturation 100%, cardiac output 5 L/min with PaO2 100 mm Hg gives 1020 mL O2/min; 1.5 L/min gives 306; increasing PaO2 to 500 at the same low flow gives 324. Teal represents hemoglobin-bound oxygen, gold dissolved oxygen. RESUS FIRST PRINCIPLES / FIGURE 01 Oxygen delivery needs content and flow Section II • What normal circulation accomplishes DO₂ = cardiac output × arterial O₂ content × 10 DO₂: mL O₂/min · Cardiac output: L/min · CaO₂: mL O₂/dL The factor 10 converts liters to deciliters. CaO₂ ≈ (1.34 × Hb × SaO₂) + (0.003 × PaO₂) Hb in g/dL; SaO₂ as a fraction; PaO₂ in mm Hg. Normal hemoglobin species assumed. ILLUSTRATIVE CALCULATIONS — NOT PATIENT DATA OR CPR TARGETS Reference flow CO 5 L/min · PaO₂ 100 mm Hg 1020 Low flow CO 1.5 L/min · PaO₂ 100 mm Hg 306 Same low flow, higher PaO₂ CO 1.5 L/min · PaO₂ 500 mm Hg 324 DO₂ · mL/min Hb-bound O₂ Dissolved O₂ All rows: Hb 15 g/dL and SaO₂ 1.00. Raising PaO₂ adds little once Hb is saturated. Hypoxemia and anemia change the problem: restore oxygen content as well as flow. Quantitative illustration • Values calculated from the displayed equation; bars share a zero baseline.

Figure

Oxygen delivery is the product of flow and arterial oxygen content. These calculated examples hold hemoglobin and saturation constant to isolate the contributions of flow and dissolved oxygen; they are not expected CPR outputs or treatment targets.

Sourceshttps://resus-first-principles.vercel.app/cases/adult-cardiac-arresthttps://www.rcemlearning.org/modules/oxygen-in-human-physiology/lessons/investigations-4/topic/oxygen-delivery/

Held constant in these predictions: hemoglobin and the oxygen-binding curve. Severe anemia from hemorrhage lowers content at any saturation, and carbon monoxide or methemoglobin lowers the functional content while the measured PaO2 may look normal. Pulse oximetry is unreliable during low flow, so content usually cannot be measured until circulation returns. The oximeter depends on a pulsatile signal from flowing blood, which is part of why it fails during CPR. Pressure is not a substitute for any of this: a vasoconstrictor can raise arterial pressure while flow to a constricted bed falls. After ROSC, when saturation can be measured, the ranges in 9.1 apply.

Delivery is supply, not use. The tissues take what they need from the delivered oxygen, and what they leave returns in venous blood; when delivery falls, extraction rises, but only so far; below a critical level of delivery it can no longer keep up, consumption falls with supply, and metabolism becomes anaerobic. That is the physical meaning of a low-flow state: oxygen may be present in the blood but not reaching the cells fast enough.

Principle

The circulation CPR creates

Compressions replace the pump.

Principle

Compressions make a gradient, and the gradient makes the flow1,5,9,13,10,2,14

In cardiac arrest the heart is no longer generating effective pressure, so nearly all coronary and cerebral blood flow during CPR depends on what compressions produce from outside the chest.

It helps to keep four quantities apart. Pressure is the force per unit area that blood exerts at one place, such as inside the aorta. A gradient is the difference between the pressures at two places. Resistance is how much the vessels between those places oppose flow. Flow is the volume of blood that actually moves through tissue, and it is set by the gradient divided by the resistance, not by any single pressure.

Resistance is why the same gradient can deliver different flow: coronary resistance is high while the compressed myocardium squeezes its own vessels and lower during release, and a vasoconstrictor such as epinephrine raises aortic pressure largely by raising peripheral resistance, which helps the heart and brain only if their own beds are not constricted to the same degree.

The heart is a muscle that never rests in health, and it extracts much of the oxygen from the blood that reaches it even at baseline, so it has little reserve to draw on when supply falls. The blood inside its chambers nourishes little beyond the innermost layer, because the ventricular walls are too thick for oxygen to diffuse far from the cavity. The myocardium therefore depends on its own circulation. That circulation begins at the aortic root, where the right and left coronary arteries arise from small openings just above the cusps of the aortic valve. From there the arteries run over the surface of the heart, send branches down into the muscle, divide into arterioles, and end in a dense bed of capillaries where oxygen leaves the blood. The blood is then collected by cardiac veins, most of which converge on the coronary sinus, a short venous channel in the groove on the back of the heart that empties into the right atrium. Some blood takes other routes, through anterior cardiac veins that enter the right atrium directly and small Thebesian veins that open into the chambers themselves, but for this model the main path is the one that ends in the right atrium.

The coronary circuit, from the aortic root across the heart muscle to the right atrium.Schematic route from the aortic root through the coronary arteries, small vessels and capillaries within the heart muscle, then cardiac veins and coronary sinus into the right atrium. Marker 1 at the aortic root shows aortic pressure here. Marker 2 at the right atrium shows right atrial pressure here. A bracket between them is labelled coronary perfusion pressure, the difference between the two, measured at the same moment, between compressions. There is no direct connection from the aorta to the right atrium.Aortic pressureduring release1Aortic rootcoronary arteries begin hereEpicardial arteriesArterioles and capillariesHeart muscle (myocardium)Cardiac veinsCoronary sinusRight atrium2Right atrial pressuredifference between these two points= coronary perfusion pressureA smaller share drains bysmall veins opening directlyinto heart chambers.The coronary circuit, from the aortic root across the heart muscle to the right atrium.Schematic route from the aortic root through the coronary arteries, small vessels and capillaries within the heart muscle, then cardiac veins and coronary sinus into the right atrium. Marker 1 at the aortic root shows aortic pressure here. Marker 2 at the right atrium shows right atrial pressure here. A bracket between them is labelled coronary perfusion pressure, the difference between the two, measured at the same moment, between compressions. There is no direct connection from the aorta to the right atrium.Aortic pressureduring releaseRight atrial pressure1Aortic rootcoronary arteriesbegin hereEpicardial arteriesArterioles andcapillariesHeart muscle(myocardium)Cardiac veinsCoronary sinusRight atrium2A smaller share drains by small veinsopening directly into heart chambers.difference between these two points= coronary perfusion pressure

Figure

The coronary circuit. Blood enters the coronary arteries at the aortic root (①), crosses the heart muscle through progressively smaller vessels, and drains mostly through the coronary sinus into the right atrium (②). Coronary perfusion pressure is the difference between the pressures at ① and ②, read at the same moment in the release phase of compression. It is a pressure difference, not a pressure at any single point and not a measure of flow. Schematic, not to scale. In studies, these pressures are measured by catheters in or near these sites.

That path explains why two pressures in such different places belong in the same calculation. Aortic pressure is the pressure at the inlet of the coronary circulation. Right atrial pressure is the pressure in the compartment that receives most of the coronary venous outflow. The right atrium supplies nothing to the coronary arteries; it enters the model only as the receiving side, the pressure that blood leaving the heart muscle has to drain against. If you trace a single red cell, it leaves the aortic root, crosses the myocardium, and arrives in the right atrium, and the pressure difference between where it started and where it ended is what moved it. A rough analogy is water running between two tanks through a pipe: the flow depends on the difference in level between the tanks and on how narrow the pipe is, not on how high the upper tank sits. The analogy fails in ways that matter here, because the coronary vessels are collapsible, their resistance changes within every compression cycle, and the flow is pulsatile rather than steady.

Aortic pressure is the pressure of the blood inside the aorta, expressed relative to atmospheric pressure. A transducer reads zero when it is open to air at the level of the right atrium, the phlebostatic level, so a reading of 35 mm Hg means the blood in the aorta is pushing 35 mm Hg harder than the atmosphere at that height. In a beating circulation this pressure comes from the left ventricle ejecting blood into an aorta that is elastic, or compliant. Each beat stretches the aortic wall, and the stretched wall stores some of the ejected energy. When the aortic valve closes, the wall recoils and keeps pushing blood onward into the arteries, including the coronary arteries, while pressure gradually falls as blood runs off into the periphery. That is why arterial pressure does not drop to zero between beats.

During CPR the ventricle is not doing that work, and the chest is. Compression raises pressure partly by squeezing the heart between the sternum and the spine and partly by raising the pressure of everything inside the chest, which pushes blood out of the heart, lungs, and great vessels toward the periphery. How much each contributes probably varies with the patient, the chest, and the technique, and neither mechanism alone accounts for the observed pressures in all settings. What matters for this argument is that compression fills and stretches the aorta, as a heartbeat would. On release, the aortic valve typically closes against the falling pressure in the ventricle, the stretched aorta recoils, and some pressure persists in the aortic root while blood continues to run off. That residual pressure is what the coronary arteries see during release. In this text it is called relaxation-phase aortic pressure; monitors and studies of CPR usually report the same quantity as arterial or aortic diastolic pressure.

Right atrial pressure is the pressure of the blood inside the right atrium, read against the same zero. It reflects how much blood is arriving from the veins, how well the right ventricle is emptying the atrium, how stiff or compliant the chamber wall is, and what is pressing on the heart from outside. That last factor is easy to forget. A catheter in the atrium measures intracavitary pressure, the pressure inside the chamber relative to atmosphere. The pressure that actually distends the chamber is the transmural pressure, the inside pressure minus the pressure surrounding the heart. When intrathoracic pressure rises, the measured intracavitary pressure rises with it even if the chamber holds no more blood.

Positive-pressure breaths are one example. Each breath raises intrathoracic pressure, and some of that rise is transmitted to the right atrium; in anesthetized patients outside of CPR, adding positive end-expiratory pressure raised measured right atrial pressure, and the animal data on ventilation rate during CPR are gathered in 5.1. The human measurement was not made during CPR and the CPR data are from animals, so the example shows the direction of the effect rather than its size in a given patient. A higher right atrial reading therefore does not mean more volume, better preload (the stretch that the blood filling a ventricle puts on its muscle just before it contracts), or more forward flow; it may simply mean that the chamber is being pressed on. Right atrial pressure in this model is not a gauge of volume. It is the pressure on the downstream side of the coronary bed.

Coronary artery pressure and coronary perfusion pressure sound alike but are different ideas. Coronary artery pressure is a local value, the pressure at one point inside a coronary artery. Coronary perfusion pressure is a difference between two locations, the inlet and the outlet of the coronary circulation. There is no conversion from aortic pressure to coronary inlet pressure, because the coronary arteries open directly from the aortic root and the two spaces are continuous; at the inlet they are essentially the same pressure. Pressure then falls along the vessels as blood meets resistance, most steeply in the small arteries and arterioles, so a reading at the inlet says nothing about the pressure beyond a narrowing. A patient with a tight stenosis can have a normal aortic root pressure and very little pressure in the territory past the obstruction.

With that picture in place, the equation is a short summary of it. Coronary perfusion pressure equals relaxation-phase aortic pressure minus the right atrial pressure measured at the same moment. Both are in millimeters of mercury, both are read against the same zero, and both must be taken during the release phase of the same cycle. Mixing phases misleads: the peak aortic pressure during compression set against the right atrial pressure during release gives a number that describes no moment the coronary bed ever experienced. Three illustrative pairs, chosen to show the arithmetic and not as targets, make the point. In pair A, aortic pressure is 35 and right atrial pressure is 10, so the gradient is 25 mm Hg. In pair B, aortic pressure is again 35 but right atrial pressure is 25, so the gradient is 10 mm Hg. Pair B is worse than A even though the inlet pressure is identical, because the outlet pressure has risen and the difference across the bed has narrowed. Pair C is hypothetical, with relaxation-phase pressures above those usually measured in human CPR: aortic pressure is 50 and right atrial pressure is 40, so the gradient is again 10 mm Hg. C looks better on the arterial line, but the higher inlet pressure is matched by a higher outlet pressure and the gradient is no wider than in B. The arithmetic shows the gradients; it does not by itself tell you the flow in any of these patients or what happens to them, because flow also depends on resistance, which these numbers do not capture.

Two pressures and the difference between themThree illustrative pairs on one scale from 0 to 60 millimetres of mercury, zeroed at the level of the right atrium. Not targets. Pair A: relaxation-phase aortic pressure 35, right atrial pressure 10, gradient 25. Pair B: relaxation-phase aortic pressure 35, right atrial pressure 25, gradient 10. Pair C, hypothetical, above those usually measured in human CPR: relaxation-phase aortic pressure 50, right atrial pressure 40, gradient 10. B and C have the same gradient although C’s aortic pressure is higher. Brackets mark the differences. There is no threshold line and no grading of the pairs.Two pressures and thedifference between themIllustrative pairs, not targetsrelaxation-phase aortic pressureright atrial pressuremm Hg0102030405060zeroed at the level of the right atriumA351035 − 10 = 25 mm HgB352535 − 25 = 10 mm HgC504050 − 40 = 10 mm Hghypothetical, above those usuallymeasured in human CPRTwo pressures and the difference between themThree illustrative pairs on one scale from 0 to 60 millimetres of mercury, zeroed at the level of the right atrium. Not targets. Pair A: relaxation-phase aortic pressure 35, right atrial pressure 10, gradient 25. Pair B: relaxation-phase aortic pressure 35, right atrial pressure 25, gradient 10. Pair C, hypothetical, above those usually measured in human CPR: relaxation-phase aortic pressure 50, right atrial pressure 40, gradient 10. B and C have the same gradient although C’s aortic pressure is higher. Brackets mark the differences. There is no threshold line and no grading of the pairs.Two pressures and the difference between themIllustrative pairs, not targetsrelaxation-phase aortic pressureright atrial pressuremm Hg6050403020100351035255040ABC35 − 10= 25 mm Hg35 − 25= 10 mm Hg50 − 40= 10 mm Hgzeroed at the level of the right atriumhypothetical, above those usuallymeasured in human CPR

Figure

Two pressures and the difference between them. Coronary perfusion pressure is relaxation-phase aortic pressure minus right atrial pressure, read at the same moment. Pairs A, B, and C are illustrative, chosen to show the arithmetic and not as targets. Pair C is hypothetical, above those usually measured in human CPR. B and C share a 10 mm Hg gradient although C’s aortic pressure is higher. The gradient alone does not give the flow, which also depends on resistance.

Data as table
Illustrative pairs, not targets. Pair C is hypothetical.
PairRelaxation-phase aortic pressureRight atrial pressureGradient
A35 mm Hg10 mm Hg35 − 10 = 25 mm Hg
B35 mm Hg25 mm Hg35 − 25 = 10 mm Hg
C50 mm Hg40 mm Hg50 − 40 = 10 mm Hg

Coronary perfusion pressure is read during the release phase of each compression, with both pressures taken at the same moment. Pair C is hypothetical, above those usually measured in human CPR.

Phase matters for a second reason, which has to do with the vessels themselves. The small coronary vessels run through the muscle, and when the chest is compressed the surrounding myocardium is squeezed along with them. Pressure at one point inside those vessels may be high, but the vessels are collapsible, and what moves blood forward is a gradient through vessels that are open. During compression the intramyocardial vessels are compressed and forward coronary flow is small. On release the muscle relaxes, the vessels reopen, and the gradient from the aortic root to the right atrium can drive blood through them. The release phase of each compression cycle is therefore when the coronary bed fills. It is a different thing from a pause in CPR. A pause stops compressions altogether, so the aorta is no longer refilled and relaxation-phase aortic pressure decays, while the release phase is a part of every cycle in which the stretched aorta is still pushing.

Read during releaseThree cells, not a measured waveform. Compression: the vessels in the heart muscle are narrowed but a lumen remains, and forward coronary flow is small. Release: the coronary bed fills mainly now, inside a window marked read here, where relaxation-phase aortic pressure and right atrial pressure are taken at the same moment. Pause: no compression, aortic pressure decays. The pause is set apart from the cycle.Read during releaseOne cycle, not a measured waveformCompressionforward coronary flowis smallReleaseRead herethe coronary bed fillsmainly nowPausePause: no compression,aortic pressure decaysRead during releaseThree cells, not a measured waveform. Compression: the vessels in the heart muscle are narrowed but a lumen remains, and forward coronary flow is small. Release: the coronary bed fills mainly now, inside a window marked read here, where relaxation-phase aortic pressure and right atrial pressure are taken at the same moment. Pause: no compression, aortic pressure decays. The pause is set apart from the cycle.Read during releaseOne cycle, not a measured waveformCompressionforward coronary flowis smallReleaseRead herethe coronary bed fillsmainly nowPausePause: no compression,aortic pressure decays

Figure

Read during release. During compression, forward coronary flow is small and the vessels in the heart muscle are narrowed but not shut. On release, the coronary bed fills mainly now. The sage window is where relaxation-phase aortic pressure and right atrial pressure are read at the same moment. A pause is not that release. Pause: no compression, aortic pressure decays. Schematic, not a measured waveform and not to scale in time.

Data as table
One cycle, read during release. Not a measured waveform.
PhaseWhat the drawing shows
CompressionVessels in the heart muscle are narrowed, with a lumen still open. Forward coronary flow is small.
ReleaseThe coronary bed fills mainly now. Read here: relaxation-phase aortic pressure and right atrial pressure, at the same moment.
PausePause: no compression, aortic pressure decays.

Coronary perfusion pressure is read during the release phase of each compression, with both pressures taken at the same moment.

For the heart, the gradient that matters is coronary perfusion pressure, and it exists during the relaxation phase. In a classic human study, return of spontaneous circulation was rare when the maximal gradient during CPR stayed below about 15 mm Hg. That is an observed association, not a treatment target, and a gradient above it did not guarantee return of circulation. Two things therefore have to happen on every cycle. The push has to be deep enough to raise aortic pressure, and the release has to be complete enough to let the chest and the heart re-expand. A deep compression followed by incomplete recoil undoes the second half, and overventilation acts on the same phase, though not in an identical way; the pig data for each are set out in 3.2, and how much either matters in a given patient depends on everything else that is happening at the same time.

The gap narrows quickly in a pause and stays narrow with ineffective compressions.Four drawings. Each has an upper line for aortic pressure and a lower line labeled right atrial pressure. The shaded gap between those lines is coronary perfusion pressure. In the open gradient the upper line is relaxation-phase aortic pressure and the lines are far apart. In the narrow gradient the aortic line is unchanged and the right atrial line is higher, so the gap is smaller; flow follows the gap (at fixed resistance). The pause drawing is labeled long pause and shows one selected state late in a long pause: there are no compressions, a dashed line marks the earlier aortic pressure, and the aortic line, labeled aortic pressure, no compressions, has fallen close to the right atrial line but does not touch it, leaving a very thin gap that narrows toward closing. In the ineffective drawing, compressions continue. Dashed lines mark the earlier pressures. The drawing shows both changes, a lower relaxation-phase aortic pressure and a higher right atrial pressure; either one alone also narrows the gap. How narrow the gap is depends on how ineffective the compressions are. No pressures are shown as numbers.Open gradientRelaxation-phase aortic pressureCoronary perfusionpressureRight atrial pressureNarrow gradientSame relaxation-phase aortic pressure.Higher right atrial pressure.Relaxation-phase aortic pressureGapRight atrial pressureSmaller gapFlow follows the gap (at fixed resistance)Long pauseNo compressions.Shown late in a long pause.Aortic pressure, no compressionsFallsRight atrial pressureGap narrows toward closingFalling toward right atrial pressure.Ineffective compressionsCompressions continue.Lower relaxation-phase aortic pressure,higher right atrial pressure,or both.Relaxation-phase aortic pressureLowerGapHigherRight atrial pressureNarrowerHow narrow depends on how ineffectivethe compressions are.Drawn with both changes; either onealone also narrows the gap.The gap narrows quickly in a pause and stays narrow with ineffective compressions.Four drawings. Each has an upper line for aortic pressure and a lower line labeled right atrial pressure. The shaded gap between those lines is coronary perfusion pressure. In the open gradient the upper line is relaxation-phase aortic pressure and the lines are far apart. In the narrow gradient the aortic line is unchanged and the right atrial line is higher, so the gap is smaller; flow follows the gap (at fixed resistance). The pause drawing is labeled long pause and shows one selected state late in a long pause: there are no compressions, a dashed line marks the earlier aortic pressure, and the aortic line, labeled aortic pressure, no compressions, has fallen close to the right atrial line but does not touch it, leaving a very thin gap that narrows toward closing. In the ineffective drawing, compressions continue. Dashed lines mark the earlier pressures. The drawing shows both changes, a lower relaxation-phase aortic pressure and a higher right atrial pressure; either one alone also narrows the gap. How narrow the gap is depends on how ineffective the compressions are. No pressures are shown as numbers.Open gradientRelaxation-phase aortic pressureCoronary perfusionpressureRight atrial pressureNarrow gradientSame relaxation-phase aortic pressure.Higher right atrial pressure.Relaxation-phase aortic pressureGapRight atrial pressureSmaller gapFlow follows the gap (at fixed resistance)Long pauseNo compressions.Shown late in a long pause.Aortic pressure, no compressionsFallsRight atrial pressureGap narrows toward closingFalling toward right atrial pressure.Ineffective compressionsCompressions continue.Lower relaxation-phase aortic pressure,higher right atrial pressure,or both.Relaxation-phase aortic pressureLowerGapHigherRight atrial pressureNarrowerHow narrow depends on how ineffectivethe compressions are.Drawn with both changes; either onealone also narrows the gap.

Figure

Coronary perfusion pressure is the gap between relaxation-phase aortic pressure and right atrial pressure. When right atrial pressure is higher and relaxation-phase aortic pressure is unchanged, the gap is smaller. When compressions pause, aortic pressure falls toward right atrial pressure and the gap narrows quickly; the longer the pause, the closer it comes to closing. When compressions continue but are ineffective, a lower relaxation-phase aortic pressure, a higher right atrial pressure, or both, can leave a gap narrower than the open gradient; how narrow depends on how ineffective they are. Flow depends on that pressure difference divided by resistance. A narrower difference, or a higher resistance, means less flow. Neither pressure alone sets coronary perfusion.

The model has limits, and they are the places where the number and the flow part company. So far the argument has leaned on the gradient and kept resistance in the background. In practice it is only half of the relation; coronary resistance, set by vascular tone, by any fixed obstruction, by the pressure within the myocardium, and by pressure inside the ventricles, determines how much flow a given gradient buys. Right atrial pressure is a reasonable stand-in for the downstream pressure because most coronary venous blood drains there, but it may not always be the effective back pressure. As an evidence note: in animal studies of ischemic myocardium outside of CPR, small coronary vessels behaved as if they closed at a pressure above the venous outlet pressure, a so-called waterfall, and when that happens flow depends on the inlet pressure minus that closing pressure rather than minus right atrial pressure. Whether and how much this operates during CPR has not been measured directly, so it is a physiological inference, not an established feature of resuscitation.

In the beating heart, perfusion of the inner layer of the left ventricle is often described with a different difference, aortic diastolic pressure minus left ventricular end-diastolic pressure, because the subendocardial vessels are compressed by the pressure in the left ventricle around them. That expression comes from a different physiology, and left ventricular end-diastolic pressure is not interchangeable with right atrial pressure.

This is why the 2025 AHA adult algorithm specifies the whole cycle, not just the push: at least 2 inches (5 cm) deep, 100 to 120 per minute, full recoil, and no leaning. Compressing on a firm surface is preferred when it is feasible and does not delay compressions. More is not automatically better. Observational data have linked depths greater than 6 cm (about 2.4 inches) with lower survival, and faster rates tend to cost depth and recoil. Compression depth also falls after about 90 to 120 seconds of continuous CPR as the compressor tires, which is why the compressor changes about every 2 minutes.

What you can observe at the bedside is limited. You can see depth, rate, and recoil, and end-tidal CO2, the partial pressure of CO2 at the end of each exhaled breath (Part VI), gives an indirect signal of flow. You usually cannot see the gradient itself, so neither compressions that look vigorous nor a single arterial number proves that blood is moving through the heart muscle. A high arterial reading can sit on top of a high right atrial pressure, and a good-looking push can be followed by a release that never comes. The model predicts that a rise in right atrial or intrathoracic pressure, or a fall in relaxation-phase aortic pressure, will tend to reduce coronary flow, unless something else widens the gradient at the same time.

The things that can be acted on are the ones the model names: complete recoil, short and infrequent pauses, ventilation that does not keep the chest pressurized, and, when invasive lines are already in place, reading the arterial and right atrial pressures together and in the same phase rather than the arterial pressure alone. The 2025 AHA guidance puts the arterial number in the same light: when an arterial line is in place, arterial diastolic pressure "can approximate coronary perfusion pressure and myocardial perfusion during CPR," but "there are inadequate adult data to suggest any specific pressure in adults." Nothing in this section is a target.

The brain depends on the same compressions, through the arterial pressure they generate. Its own gradient is opposed by intracranial and venous pressure rather than right atrial pressure, but the practical lesson is shared: poor compressions tend to fail both organs together.

Principle

Rate, depth, recoil, duty cycle, and fatigue interact1,22,24,20,19,21,23,9

How a compression moves blood

A compression moves blood by raising pressure in the heart and the chest above the pressure in the vessels outside the chest, and blood leaves toward the lower pressure.

Two mechanisms do this, and 3.1 introduced them. In the cardiac-pump description, the sternum squeezes the ventricles against the spine, the mitral and tricuspid valves typically close, and blood is pushed out through the aortic and pulmonary valves much as in a heartbeat. In the thoracic-pump description, the compression raises pressure throughout the chest, the heart behaves more like a passive conduit, and blood is pushed out of the lungs, heart, and great vessels together; valves in the large veins at the thoracic inlet are thought to keep that pressure from driving blood backward into the head and arms, so the forward path toward the arteries is favored. Echocardiographic and pressure studies during CPR have been interpreted as supporting each pattern in different patients and at different times, which is why this text treats both as contributing and does not name one as the mechanism. The balance probably varies with the patient; in one human echo study, the ventricles were compressed more in narrower chests, and heart size, hand position, and arrest duration are thought to matter as well.

Release

Release is the other half of the cycle, and it is not suction in the sense of the heart pulling blood in. When the hands come off the sternum, the elastic chest wall springs back, intrathoracic pressure falls, sometimes slightly below atmospheric, and the pressures inside the heart and great veins fall with it. Blood returns because mean systemic filling pressure in the veins outside the chest, the pressure that the stretched systemic veins exert on the blood they hold, is now higher than right atrial pressure, the same gradient described in 5.1, and the coronary arteries fill because relaxation-phase aortic pressure is held above right atrial pressure, as described in 3.1. The aortic valve typically closes under the higher pressure above it and keeps the aorta from emptying backward into the ventricle during this phase. Nothing pulls the blood; the release removes the pressure that was opposing its return.

Five variables, one cycle

The compression variables are not independent dials. Each cycle has a push phase and a release phase; duty cycle is the fraction spent pushing. Changing one variable moves the others.

Rate shortens the cycle. Above the guideline range of 100 to 120 per minute, there is less time per cycle to push to depth and to release fully, so depth and recoil tend to fall. Below it, the gradient decays between compressions. Depth raises aortic pressure, but excessive depth, above about 6 cm in observational data, has been associated with lower survival. Recoil lets the chest and heart re-expand in the relaxation phase; in a pig study in which a device held compression depth constant, incomplete recoil lowered relaxation-phase aortic pressure and narrowed the coronary gradient while right atrial pressure changed little. Duty cycle trades the two phases against each other: a longer push gives more time for forward flow, a longer release gives more time for refilling and coronary filling. The optimal duty cycle is not known; the 2025 guideline says it may be reasonable to make compression and recoil times approximately equal (COR 2b, LOE C-EO), and calls the optimum a knowledge gap.

An illustrative calculation, from the guideline numbers rather than from measurement, shows why rate and duty cycle are tied together. At 100 compressions per minute each cycle lasts 0.6 seconds; at 120 per minute, 0.5 seconds. With compression and recoil times approximately equal, the release phase available for refilling and coronary filling is about 0.3 seconds at the lower rate and about 0.25 seconds at the upper. Beyond the range the release gets shorter still, and any leaning eats further into it. These figures show the arithmetic of the cycle, not targets, and they do not say how much flow occurs in each phase.

These figures show the arithmetic of the cycle, not targets, and they do not say how much flow occurs in each phase.
RateCycleRelease
100/min0.6 sabout 0.3 s
120/min0.5 sabout 0.25 s

Ventilation acts on the same chest. A positive-pressure breath raises intrathoracic pressure, and if breaths come too often or are held too long, the chest spends more of each minute at a higher pressure, which tends to oppose venous return during release in the way 5.1 describes. The animal and human evidence on ventilation rate during CPR is gathered in 5.1. The guideline rates are 30 compressions to 2 breaths without an advanced airway and 1 breath every 6 seconds with one.

Fatigue degrades all of them together. Depth begins to fall after about 90 to 120 seconds, while rate holds, which is why changing compressors at about 2 minutes is built into the cycle. The practical model is that a compression is good only if all four variables are within range at once, and that a change aimed at one, such as pushing faster, should be judged by what it does to the others. Feedback on depth and rate is one way teams see what the eye misses. End-tidal CO2 gives an indirect signal of the output those compressions produce, with the limits set out in Part VI. During arrest, real-time audiovisual feedback on CPR quality is reasonable (COR 2a, LOE B-R), though its association is with ROSC and survival to discharge rather than survival with favorable neurological outcome; in training, feedback devices are recommended (COR 1, LOE A).

Principle

Pauses cost more than their length1,2

Coronary perfusion pressure is built, not switched on.

Over the first several compressions after a pause, aortic pressure climbs toward a plateau. When compressions stop, it falls almost at once. A pause therefore costs its own seconds plus the run of compressions needed to rebuild the gradient afterward. Several short pauses can cost more perfusion than their total time suggests, because each one restarts the climb.

Chest compression fraction, the share of the resuscitation during which compressions are actually happening, is the bedside measure of this. The 2025 adult BLS guidance says a fraction of at least 60% may be reasonable, based on observational data that are mixed, and high-performing teams may exceed 80%.

Some pauses are necessary: two breaths in 30:2 CPR without an advanced airway, a rhythm or pulse check, and delivery of a shock. The job is to make them few and short. Professionals often take longer than 10 seconds to decide whether a pulse is present, so the instruction is to restart compressions if a pulse is not definitely felt within about 10 seconds.

The perishock pause, the gap just before and after a shock, is especially costly because it comes when a successful shock most needs perfused myocardium. Two randomized trials found no survival benefit from pausing after a shock to inspect the rhythm before restarting CPR, and failing to restart promptly is associated with less return of spontaneous circulation.

How the airway changes the plan: without an advanced airway, the compression cycle already includes a pause for two breaths, so a compressor swap or a quick look can be folded into a pause that would happen anyway. Once an advanced airway is in, breaths are given continuously without pausing compressions, so there is no breath pause to share. The only planned pauses left are rhythm checks and shocks, and compressor changes belong there.

The limitation: the build-up of pressure after a pause comes from animal and limited human measurements, and the exact number of compressions needed varies. The direction is consistent, but the curve is not something you can see at the bedside.

Schematic, not measured data. When compressions continue, coronary perfusion pressure builds. When they pause, it falls. When compressions resume, it builds again along a continuous rise.A timeline of continuous curves, not a measured curve and not a numbered scale. The line rises while compressions continue. At the pause, an arrow shows perfusion pressure falling to the baseline. After the pause, a smooth unlabeled ramp rises again, with no compression count and no duration. No axis values are shown.Schematic, not measured dataTimelinePerfusion pressureContinuous rise, not a counted run.BuildsPausefallsRebuildsTime

Figure

Schematic, not measured data. When compressions continue, coronary perfusion pressure builds. When they pause, it falls. When compressions resume, it builds again. The rise is continuous and does not mark a set number of compressions or a duration. There is no scale and no measured curve.

Questions for this part (5)

Question 3.1

Prediction

Predict: a compressor is pushing to a good depth but leaning on the chest between compressions. What happens to coronary flow, and why does it surprise people?9

Commit to an answer before revealing.

Reveal answer for Question 3.1

Coronary flow is likely to fall even though each push looks deep, because leaning lowers relaxation-phase aortic pressure and narrows the gradient.

Why

Coronary perfusion pressure is relaxation-phase aortic pressure minus right atrial pressure at the same moment. In a pig study, incomplete recoil lowered relaxation-phase aortic pressure and narrowed the gradient, while right atrial pressure changed little. The penalty therefore falls mainly on the inlet side, during the very phase when the coronary arteries fill.

Assumption

The pig findings apply in direction, if not in size, to the patient in front of you, and nothing else is widening the gradient at the same time.

Common misconception

The belief that perfusion is made by the push. The push creates aortic pressure; the release is what lets that pressure become coronary flow. Recoil is part of the work, not a rest from it.

Question 3.2

Transfer

Transfer: in the cath lab, a patient in arrest has an arterial line and a central venous line. During compressions that look deep and fast, the relaxation-phase aortic pressure is 30 mm Hg and the central venous (right atrial) pressure is 25 mm Hg. What does the gradient tell you, and what would you check?9,1,13,14

Commit to an answer before revealing.

Reveal answer for Question 3.2

The coronary perfusion pressure is only about 5 mm Hg, well below the maximal gradients seen in patients who regained circulation in the classic human study (about 15 mm Hg or more), so coronary flow is probably poor despite vigorous-looking compressions. The high right atrial pressure is the thing to explain: check the ventilation rate and pressures, and look for causes that raise right atrial pressure, such as tamponade, tension pneumothorax, or a massive pulmonary embolus. Check recoil too, because it mainly affects the aortic side of the gradient.

Why

Coronary perfusion pressure is relaxation-phase aortic pressure minus right atrial pressure at the same moment. A right atrial pressure close to aortic pressure nearly closes the gradient, however deep the compressions. Rising intrathoracic pressure from rapid or forceful ventilation, and obstruction around or beyond the right heart, can raise right atrial pressure. Incomplete recoil, in animal data, mainly lowers relaxation-phase aortic pressure rather than raising right atrial pressure.

Assumption

The catheters are correctly zeroed and positioned, and the pressures are read during the relaxation phase.

Common misconception

The belief that compressions that look good must produce good perfusion. The pressures show what the eye cannot.

Question 3.3

Evidence boundary

Evidence boundary: why is the depth target written as at least 5 cm rather than as deep as possible, and how confident should you be in the upper limit?1

Commit to an answer before revealing.

Reveal answer for Question 3.3

Because depths above about 6 cm have been associated with lower survival. That limit comes from observational data, so it is a caution about excess rather than a precisely measured ceiling.

Why

Deeper compressions raise aortic pressure, but beyond a point the observational data no longer show benefit, and injury such as rib and visceral trauma becomes a concern.

Assumption

The association reflects depth itself rather than other features of the resuscitations in which very deep compressions occurred. Observational data cannot fully separate those.

Common misconception

The belief that a guideline number marks a sharp physiological threshold. Here the number marks the edge of what the evidence supports.

Question 3.4

Prediction

Predict: the team stops compressions for 20 seconds to feel carefully for a pulse and study the monitor. What happens to coronary perfusion pressure during the pause, and after it?1

Commit to an answer before revealing.

Reveal answer for Question 3.4

It falls almost immediately during the pause, and it stays below its plateau for several compressions afterward while it rebuilds. The real cost is longer than 20 seconds.

Why

Aortic pressure during CPR exists only because compressions produce it. When they stop, it decays toward right atrial pressure and the gradient narrows quickly; the longer the pause, the closer it comes to closing. When compressions resume, the first several build aortic pressure back up before coronary flow returns to where it was.

Assumption

Compressions before the pause were good enough to build a meaningful gradient. If they were poor, the pause costs less only because there was less to lose.

Common misconception

The belief that a careful pulse check is free because it is diagnostic. A prolonged search buys little extra certainty and spends perfusion. Restart compressions if a pulse is not definitely felt within about 10 seconds.

Question 3.5

Transfer

Transfer: in the cath lab, compressions are paused every 30 seconds so fluoroscopy can image the coronary arteries. Each pause lasts about 10 seconds. Using what you know about pauses, what is the cost, and what alternative does the guideline support?3,1

Commit to an answer before revealing.

Reveal answer for Question 3.5

Each pause restarts the climb of coronary perfusion pressure, so frequent short pauses cost more perfusion than their total time suggests. Mechanical CPR is reasonable in the cath lab, because it allows imaging and intervention without stopping compressions.

Why

Aortic pressure falls quickly when compressions stop and takes several compressions to rebuild. Repeated pauses keep the gradient below its plateau for most of the time. A mechanical device removes the operator from the field and keeps compressions continuous during imaging.

Assumption

A device is available and can be placed without a long interruption.

Common misconception

The belief that brief pauses are harmless if each is short. Their cost is multiplied by how often they occur.

Principle

Electrical activity and mechanical output

A rhythm is electrical; output is mechanical.

Principle

Electrical activity is not mechanical activity, and neither is perfusion2,5,6,32,33,34

Three different things can be true or false about the heart in arrest.

It can have organized electrical activity. It can contract. And those contractions can produce enough flow to perfuse the body. A monitor shows only the first. VF and pulseless VT have electrical activity that does not produce effective contraction. PEA has organized electrical activity with too little mechanical output to make a pulse. Asystole has neither.

Each of the three has a location and a physical form. The electrical event begins in specialized tissue: normally the sinus node in the wall of the right atrium, then the atrioventricular node, the His bundle, the bundle branches, and the Purkinje fibers that spread the impulse through the ventricular muscle. Depolarization is a wave of change in the voltage across cell membranes, carried by ions moving through channels, and the surface ECG records the sum of those voltage changes from outside the body. Contraction is a separate, chemical and mechanical event inside each muscle cell: depolarization lets calcium enter and be released from internal stores, calcium allows the contractile proteins to bind and shorten, and the process consumes ATP. Flow is a third step again: shortening of the ventricular wall raises pressure in the chamber, and only when that pressure exceeds aortic pressure does the aortic valve open and blood leave. Each link can fail while the one before it survives. An ischemic, acidotic, or energy-depleted cell can depolarize without contracting usefully, and a heart that contracts can still eject little if it has nothing to fill it or something blocking its outflow.

VF and pulseless VT are shockable because their failure is in the first link. In VF, wavelets of depolarization circulate chaotically through the ventricles, usually by re-entry, so different regions are activated at different times and no coordinated contraction occurs. In pulseless VT, the rhythm is organized but too fast, or the myocardium too damaged, for the ventricles to fill and eject a pulse. A shock passes current through the heart and depolarizes enough of the myocardium at once that the circulating wavefronts have no excitable tissue left to enter, and they stop. What follows depends on whether the conduction system and myocardium can then generate and respond to an organized impulse. A shock does not make the heart contract, and a shock is not indicated for PEA or asystole, where there is no re-entrant rhythm to terminate.

PEA covers a range of mechanical states that the monitor cannot separate. At one end, organized depolarization produces no detectable contraction at all, true electromechanical dissociation. At the other, the ventricles contract, sometimes vigorously, but eject too little to make a palpable pulse, a state often called pseudo-PEA. The difference matters because it points to different causes. A heart contracting around little blood suggests a filling or obstruction problem such as hypovolemia, tamponade, tension pneumothorax, or massive pulmonary embolism; a heart that is barely moving suggests advanced ischemia, acidosis, or a metabolic or toxic cause. Point-of-care ultrasound can show cardiac motion, and an arterial line can show small pressure pulses that a finger cannot feel. Point-of-care ultrasound can be used by an experienced operator when it does not interrupt CPR, though its usefulness during arrest is not well established, and seeing motion on ultrasound is not the same as measuring flow. Asystole is the absence of detectable electrical activity, and with it the absence of contraction; before accepting it, it is standard practice to check that leads and gain are not hiding a fine VF.

For resuscitation, the practical rule is that each kind of observation answers only its own question. The monitor answers whether the heart is depolarizing in an organized way and whether a shock is indicated. Ultrasound answers whether it is moving, and sometimes why it is not filling. A pulse, an arterial waveform, or a sustained rise in end-tidal CO2 answers whether it is producing flow. Using one to answer another's question is where errors come from: an organized rhythm read as a perfusing heart, or visible cardiac motion read as adequate output. This is reasoning from physiology; the guideline treatment of PEA and asystole, compressions, epinephrine, and the search for a cause, does not change with the subtype, and no trial has tested whether treating PEA by subtype improves survival.

Shockable rhythms are electrical problems with an electrical treatment. In dog experiments, fibrillation stopped when a shock depolarized a critical mass of myocardium at once; that gives an organized rhythm a chance to take over. It works best early. In the ARREST registry of witnessed out-of-hospital arrest with an initial rhythm of VF, the first shock terminated VF about 93% of the time when it came within 6 minutes and about 75% of the time when it was delayed past 16 minutes. Each minute of delay to the first shock was associated with a relative reduction of about 6% in survival to discharge.

Time changes the myocardium as well as the odds. As VF continues, the myocardium uses up its energy stores, and a shock is less likely to produce an organized rhythm that can contract. CPR before the shock can restore some of that substrate, which is why prolonged VF and freshly witnessed VF are not the same problem.

The 2025 ALS guidelines prefer a single shock to stacked shocks, followed by immediate CPR for about 2 minutes. Whether stacked shocks are better in a monitored, witnessed arrest is unknown. Use a biphasic defibrillator when one is available, at the manufacturer's energy. If that energy is unknown, the maximal dose on that device may be used; the algorithm gives a typical biphasic initial range of 120 to 200 joules as an example. A monophasic device, if that is all you have, is set at 360 joules. Later shocks are at least that same energy, and a higher energy may be considered when the device can escalate and a perfusing rhythm has not returned.

The limit of the model: an organized rhythm after a shock does not prove that the heart is perfusing. That question is answered by a pulse, an arterial line, or a sustained rise in end-tidal CO2, not by the monitor. The usefulness of pad vector change and double sequential defibrillation for VF still present after three or more shocks has not been established, so fix pad contact, pad position, and CPR quality before adding an unproven technique.

Principle

After the shock: post-shock mechanical failure, recurrent and incessant VF1,2

A successful shock ends VF electrically; it does not restore pumping.

After defibrillation the myocardium has been ischemic for the duration of VF and has just been depolarized en masse. It often produces an organized rhythm with weak or no effective contraction for a period afterward, so the first post-shock rhythm is commonly asystole or PEA before any pulse returns. This is the mechanical reason to resume compressions immediately after a shock without pausing to inspect the rhythm or feel for a pulse: compressions supply coronary flow to a stunned myocardium during the interval when it most needs it, and the rhythm and pulse are checked at the end of the 2-minute cycle. Randomized trials of pausing to analyze after the shock found no survival benefit.

Two mechanisms look the same on a single rhythm check. In incessant VF, the shock did not terminate VF. In recurrent VF, the shock terminated VF and it returned, usually hidden by the CPR that followed; AHA 2025 states this accounts for about 80% of VF seen at post-shock rhythm checks. Because the mechanism usually cannot be known during CPR, the guideline uses 'persisting VF/pVT' for VF/pVT that remains after 3 or more consecutive shocks. Telling them apart requires seeing the rhythm in the seconds after the shock, before CPR artifact hides it. AHA notes that recurrence is usually obscured by the CPR that follows, and that reliable ways to distinguish the two during ongoing CPR still need investigation. Incessant VF points to the shock: pad position, contact, energy, and the state of the myocardium. Recurrent VF points to a substrate that keeps re-triggering it, and AHA notes it may be better treated with post-shock rhythm stabilization than by changing a shock that worked. Antiarrhythmics may be considered for VF unresponsive to defibrillation. The usefulness of vector change and double sequential defibrillation for persisting VF/pVT after 3 or more consecutive shocks has not been established (COR 2b, LOE B-R). The incessant/recurrent distinction is defined in the AHA Part 9 synopsis and carries no COR/LOE of its own.

Ending VF is not the same as restoring flowElectrical organization leads toward contraction and circulation, but neither transition is guaranteed. Incessant VF continues through the shock; recurrent VF terminates and later returns. CPR artifact may hide the interval. Immediate post-shock CPR supports circulation. RESUS FIRST PRINCIPLES / FIGURE 02 Ending VF is not the same as restoring flow Sections 4.1–4.2 • Electrical activity, contraction, and perfusion Electrical organization ECG shows activation. It does not show output. Mechanical contraction Myocardium must respond. Ischemia can impair it. Effective circulation Needs filling and ejection, with an open flow path. A shock can terminate VF without producing a pulse. After a shock, resume CPR immediately in the standard adult arrest sequence. WHY VF AT THE NEXT CHECK DOES NOT PROVE THE SHOCK FAILED Incessant VF VF never terminates Recurrent VF VF ends, then returns VF shock VF shock VF continues VF terminated VF returns The bedside limitation CPR artifact can hide the intervening rhythm. These are mechanisms, not a reason to pause compressions and watch the monitor. Organized rhythm or visible cardiac motion alone does not establish ROSC. Conceptual timelines, not durations • VF = ventricular fibrillation; ROSC = return of spontaneous circulation.

Figure

Electrical organization, contraction, and effective circulation are distinct. VF can persist because a shock did not terminate it, or recur after successful termination. The timelines illustrate the distinction without implying a duration.

Sourceshttps://cpr.heart.org/en/resuscitation-science/cpr-and-ecc-guidelines/adult-advanced-life-supporthttps://cpr.heart.org/en/resuscitation-science/cpr-and-ecc-guidelines/adult-basic-life-support

Questions for this part (4)

Question 4.1

Prediction

Predict: a monitored patient loses a pulse and the screen shows VF. What changes the outcome more in the first minute, a shock or epinephrine?2,6

Commit to an answer before revealing.

Reveal answer for Question 4.1

The shock. Defibrillation is what terminates VF, and delay to the first shock costs survival. Epinephrine in a shockable rhythm comes after initial shocks have failed, then 1 mg every 3 to 5 minutes.

Why

VF is an electrical failure. Epinephrine can raise relaxation-phase aortic pressure during CPR, which helps perfusion, but it does not organize the rhythm. Only depolarizing the myocardium can do that, and the chance of success falls with each minute.

Assumption

A defibrillator is immediately available. When it is not, compressions are what keep the myocardium viable until it arrives.

Common misconception

The belief that a drug should come before a procedure. In witnessed, monitored VF, the immediate action is one shock and an immediate return to compressions.

Question 4.2

Transfer

Transfer: after several minutes of CPR for an unwitnessed arrest, the first rhythm check shows VF. Why is the answer different from stacking shocks the way you might for a freshly witnessed arrest?2

Commit to an answer before revealing.

Reveal answer for Question 4.2

Deliver one shock at the device's recommended biphasic energy, or its maximum if that setting is unknown, then resume CPR for about 2 minutes. Stacked shocks extend time off the chest when the myocardium most needs perfusion.

Why

After minutes of untreated or partly treated VF, the myocardium's energy stores are depleted. Compressions between shocks restore some coronary flow and improve the conditions for the next shock. Back-to-back shocks keep compressions stopped and let coronary perfusion pressure fall.

Assumption

This is an arrest that has already had minutes of CPR. The single-shock preference rests on less pause time, not a higher success rate per shock, and whether stacked shocks are better in a monitored, witnessed arrest is unknown.

Common misconception

The belief that more shocks, sooner, must be better. If a later shock is needed and the device can escalate, a higher energy may be considered, but each shock still comes inside the CPR cycle. Vector change and double sequential defibrillation are not established treatments for VF that persists after three or more shocks.

Question 4.3

Transfer

Transfer: after a shock and two minutes of CPR, the monitor shows a narrow, organized rhythm. A team member says the shock worked. What can and can't you conclude?5

Commit to an answer before revealing.

Reveal answer for Question 4.3

You can conclude that the electrical problem has changed. You cannot conclude that the heart is perfusing until you confirm a pulse or another sign of circulation.

Why

An organized rhythm means the myocardium is depolarizing in sequence. Whether that produces contraction, and whether contraction produces enough flow, are separate questions. Without a pulse, this is PEA, and it calls for continued CPR, epinephrine, and the search for a cause.

Assumption

The pulse check is brief and the finding is clear. If a pulse is not definitely felt within about 10 seconds, compressions resume.

Common misconception

Reading the monitor as a measure of circulation. It measures electrical activity, which is necessary for perfusion but not enough to prove it.

Question 4.4

Prediction

Predict: immediately after a shock, someone wants to hold compressions and watch the monitor to see whether it worked. What is likely to happen if you comply?2

Commit to an answer before revealing.

Reveal answer for Question 4.4

You lose perfusion at the moment the myocardium most needs it, and watching does not change whether the shock worked. Resume compressions at once and check the rhythm at the end of the two-minute cycle.

Why

Even when a shock terminates VF, the heart often produces little or no effective output for the first moments afterward. Compressions supply coronary flow while it recovers. Holding off leaves a stunned myocardium unperfused.

Assumption

A brief pause would not detect anything that changes the immediate action. In randomized trials, pausing after defibrillation to analyze the rhythm did not improve survival.

Common misconception

The belief that VF found at the next rhythm check means the shock failed and you should have watched. Much of that VF is recurrence during CPR, not a reason to have stayed off the chest.

Principle

Ventilation and heart-lung interaction

Ventilation supplies oxygen and changes the circulation.

Principle

Ventilation is gas exchange and a circulatory intervention1,2,10,15,16,17,18,14

Compressions move blood, and that blood still has to carry oxygen while carbon dioxide is cleared.

Arterial oxygen content falls if ventilation is left out for long, especially in asphyxial arrest. For health care professionals, the 2025 BLS guidance says it is reasonable to give both compressions and ventilations, with enough tidal volume to see the chest rise, while avoiding both hypoventilation and hyperventilation.

Breathing also changes the circulation, and to see how, it helps to start with where the returning blood is and what pushes it. Most of the blood in the systemic circulation sits in the veins and venules, a large, thin-walled, distensible reservoir spread through the abdomen, the limbs, and the skin. If the heart stopped and flow ceased everywhere, pressures throughout the systemic vessels would move within seconds toward a common value, and that pressure is the mean systemic filling pressure. It is the pressure that the volume of blood exerts on the stretched walls of the systemic vessels, most of all the veins, measured in mm Hg against the same atmospheric zero as every other pressure in this text. It is not produced by the heart. It exists because the vessels hold more blood than they can contain without being stretched.

That distinction between holding and stretching is the core of the idea. Part of the blood in the veins only fills them to their resting shape and exerts almost no pressure; this is the unstressed volume. The blood beyond that stretches the walls, and only this stressed volume produces filling pressure. How much pressure a given stressed volume produces depends on venous compliance, the change in volume per change in pressure (mL per mm Hg): compliant veins accept a lot of blood with a small rise in pressure, stiff or constricted veins much less. Mean systemic filling pressure therefore rises when blood or fluid is added, and when sympathetic tone or a vasopressor constricts the veins, which is thought to shift blood from unstressed to stressed volume. In ICU patients, raising or lowering norepinephrine moved estimated filling pressure in the same direction, but it also changed the resistance to venous return, so cardiac output did not always rise. These are estimates outside of CPR, and the volume shift itself is inferred rather than measured. Pressure from outside the veins can act in either direction: in dogs, raised abdominal pressure pushed blood from the abdominal veins toward the chest, but it impeded return when the abdominal veins collapsed. It falls with blood or fluid loss and when venous tone is withdrawn, as after induction drugs. Pressure, volume, and distension are three different things here: the same total blood volume can produce different filling pressures depending on tone, and a vein can be full without being under much pressure.

Venous return is a flow, measured in liters per minute, and it needs a gradient like any other flow. Blood moves from the peripheral veins, at roughly mean systemic filling pressure, toward the right atrium, so the pressure it flows against is right atrial pressure. This is the same right atrial pressure that sits on the outlet side of the coronary bed in 3.1, now acting as the back pressure for the whole systemic venous return. A catheter reads it as intracavitary pressure relative to atmosphere, and that is the relevant value here, because most peripheral veins, outside the chest, sit at roughly atmospheric surrounding pressure; abdominal veins sit at abdominal pressure. When intrathoracic pressure rises, intracavitary right atrial pressure rises with it, even though the pressure actually distending the atrium may not change and the atrium may hold no more blood. For venous return, the rise in the measured value is what matters, because it narrows the difference that drives blood into the chest.

With those pieces in place, the relation can be written. Venous return is driven by the difference between mean systemic filling pressure and right atrial pressure. Written out, venous return equals mean systemic filling pressure minus right atrial pressure, divided by the resistance to venous return, with the pressures in mm Hg, venous return in liters per minute, and resistance in mm Hg per liter per minute. The resistance to venous return does not change that gradient; it sets how much flow a given gradient produces. An illustrative example, with numbers chosen only to show the arithmetic and not as measured or target values: if filling pressure is 12 mm Hg and right atrial pressure is 4, the gradient is 8 mm Hg; if a breath raises right atrial pressure to 9 while filling pressure stays at 12, the gradient falls to 3. In a hypovolemic patient whose filling pressure starts at 7, the same rise in right atrial pressure from 4 to 7 closes the gradient entirely. The arithmetic does not give the flow in any real patient, because filling pressure can move with the breath and resistance is not known.

Every positive-pressure breath is also a circulatory event. A positive-pressure breath raises intrathoracic pressure, and with it right atrial pressure. If right atrial pressure rises more than filling pressure over that breath, the gradient narrows, and with venous resistance unchanged, venous return falls. More breaths, or breaths held longer, keep that gradient narrowed for more of each minute. With less blood entering the heart, each compression has less to eject, and coronary perfusion pressure tends to fall. The prediction weakens when filling pressure rises with the breath, and the same rise in right atrial pressure costs a smaller fraction of venous return when filling pressure starts high: a volume-loaded or venoconstricted patient tolerates the same breath better, while a hypovolemic patient loses venous return sooner. In a study of 10 anesthetized adults undergoing defibrillator implantation, holding airway pressure at 15 rather than 0 cmH2O during apnea raised right atrial pressure and mean systemic filling pressure (measured during brief induced VF) by similar amounts, so the gradient was unchanged, yet left ventricular stroke volume fell by a mean of 23% (with wide variation); that is one bounded observation, not a description of the arrested circulation during CPR. The guideline names the harms of excessive ventilation directly: gastric inflation, regurgitation, aspiration, and decreased cardiac output.

One downstream pressure, two different gradientsTwo unscaled pressure diagrams. With upstream pressure fixed, increasing right atrial pressure narrows the venous-return gradient on the left and coronary perfusion gradient on the right. Positive-pressure ventilation can also change upstream pressure and resistance, so its net effect is conditional. RESUS FIRST PRINCIPLES / FIGURE 03 One downstream pressure, two different gradients Section 5.1 • How positive pressure can interfere with circulation Venous return Qᵥᵣ ≈ (Pms − Pra) / Rᵥᵣ Systemic veins → right atrium Coronary perfusion CPP ≈ Pao,relax − Pra,relax Coronary flow also depends on resistance Hold upstream pressure constant Pms Pra before Pra higher smaller gap Hold upstream pressure constant Pao,relax Pra,relax before Pra,relax higher smaller gap If Pra rises more than Pms, the venous-return gradient narrows. At unchanged venous resistance, less blood returns to the right heart. At unchanged coronary resistance, a higher Pra,relax means less coronary flow. WHY THIS IS A CONDITIONAL MODEL Positive pressure may raise both Pms and Pra. Resistance to venous return, RV afterload, and LV loading may also change; net cardiac output is not fixed by the rise in Pra alone. This is not a complete model of positive-pressure ventilation. Pms: mean systemic filling pressure · Pra: right atrial pressure · Qᵥᵣ: venous return Pao,relax: relaxation-phase aortic pressure · Rᵥᵣ: resistance to venous return CPP: coronary perfusion pressure · Pra,relax: right atrial pressure during relaxation Schematic • No measured pressure scale. The two panels do not imply equal pressures or equal gradients.

Figure

Right atrial pressure is the downstream pressure in two different models. Venous return depends on the systemic filling-pressure gradient and venous resistance; coronary perfusion during CPR depends on the relaxation-phase aortic–right atrial gradient and coronary resistance.

Sourceshttps://resus-first-principles.vercel.app/cases/adult-cardiac-arresthttps://pubmed.ncbi.nlm.nih.gov/10710387/https://cpr.heart.org/en/resuscitation-science/cpr-and-ecc-guidelines/adult-basic-life-support

During CPR this reasoning applies with two differences. The heart is not lowering right atrial pressure by ejecting, so the release phase of each compression, when the chest recoils and intrathoracic pressure falls, is the main opportunity for the right atrial pressure to drop below filling pressure and for blood to return. And the same right atrial pressure now sits downstream of two gradients at once: the venous return that refills the heart and the coronary perfusion that nourishes it. A rise in intrathoracic pressure that raises right atrial pressure therefore tends to narrow both. This is physiological reasoning built from the relations above; mean systemic filling pressure is not measured during clinical resuscitation, and the recommendation to avoid excessive ventilation rests on the guideline's statement of harms and on animal and observational data rather than on trials that titrated ventilation to a venous-return target.

The evidence for the circulatory cost of extra breaths during CPR is mostly animal. In pigs, faster ventilation rates during CPR raised mean intrathoracic pressure and lowered coronary perfusion pressure and survival; in people, very fast bagging has been observed during resuscitation, but the hemodynamic and survival effects come from the animal data. The pig result fits the mechanism above, since each extra breath adds time at raised intrathoracic pressure, which works against the venous-return gradient and the coronary gradient during the same release phase. This is the home of that finding; the sections on coronary perfusion and CPR mechanics point here rather than restating it.

Breaths also have to be judged by what they do for oxygen delivery, which is flow multiplied by arterial oxygen content (Part II). A breath raises content only by refreshing alveolar oxygen so that hemoglobin passing the lungs can load. During CPR pulmonary blood flow is low, so the blood that has to be oxygenated each minute is small, and once the hemoglobin leaving the lungs is nearly saturated, further breaths add almost no content. Their effect on intrathoracic pressure, however, acts on the flow term. Because content and flow multiply, a small gain in one cannot make up for a larger loss in the other. An illustrative calculation, with numbers chosen only to show the arithmetic and not measured in any patient: if faster bagging raised arterial content from 19 to 19.5 mL O2/dL, about 3%, but lowered the output of compressions from 1.5 to 1.2 L/min, 20%, delivery would fall from about 285 to about 234 mL O2 per minute (L/min times mL/dL times 10). The opposite error is real too. Ventilation that is too sparse lets content fall, especially in asphyxial arrest, which is why the guidance asks for neither hypoventilation nor hyperventilation.

More is therefore not better for reasons that are easy to run together. Beyond the point where the blood is saturated, extra breaths add little oxygen. They lengthen the time the chest spends at raised pressure, which tends to oppose venous return and narrow the coronary gradient. And they carry the harms the guideline names, gastric inflation, regurgitation, and aspiration. After ROSC the same excess acquires one more cost, because a falling PaCO2 constricts the cerebral arterioles, as set out in the post-ROSC targets.

The airway state determines the rhythm of breathing. Without an advanced airway the ratio is 30 compressions to 2 breaths. With an advanced airway in place, give 1 breath every 6 seconds (10 breaths per minute) without pausing compressions. Begin with a bag-mask and oxygen. If placing an advanced airway would interrupt compressions, defer it until initial CPR and defibrillation have failed, or until there is ROSC.

Principle

Peri-intubation deterioration and gas trapping3

Intubation changes three things at once, and each can push a fragile circulation into arrest.

Induction drugs remove sympathetic tone, lowering mean systemic filling pressure. Positive-pressure ventilation raises intrathoracic and right atrial pressure. And the transition can remove a patient's own respiratory compensation for a metabolic acidosis if the ventilator delivers less minute ventilation than the patient was generating. A patient who was already short of volume or acidemic before the tube has the least reserve.

Gas trapping adds a fourth mechanism. When expiration is too short for the lungs to empty, as in severe asthma and, by the same physiology, in COPD or rapid bagging, each breath starts before the last has left. Volume and pressure accumulate in the alveoli (intrinsic PEEP, or auto-PEEP), intrathoracic pressure rises, right atrial pressure rises, and venous return falls by the same mechanism as a tension pneumothorax, but on both sides. The prediction is falling blood pressure, then PEA, with high airway pressures and quiet but equal breath sounds. Brief disconnection from the bag or ventilator lets the chest empty and may relieve hyperinflation; a rise in pressure soon after is consistent with gas trapping. The graded scope is therapeutic and limited to life-threatening asthma refractory to standard therapies, where active exhalation maneuvers may be considered (COR 2b, LOE C-EO); extending it to COPD or rapid bagging is physiological reasoning, not a graded recommendation. A sudden rise in peak pressure or difficulty ventilating in severe asthma should prompt evaluation for tension pneumothorax, which disconnection does not relieve. In life-threatening asthma, a low respiratory rate and tidal volume is reasonable (COR 2a, LOE C-LD).

When the next breath arrives too soonTwo flow-time schematics with inspiration above zero and expiration below. The first returns to zero before each breath. In the second, the next inspiration starts while expiratory flow remains negative. A downstream sequence links trapping, intrinsic PEEP, and possible circulatory impairment. RESUS FIRST PRINCIPLES / FIGURE 04 When the next breath arrives too soon Section 5.2 • Expiratory flow reveals incomplete emptying SCHEMATIC FLOW–TIME TRACES • INSPIRATION ABOVE ZERO Enough time to exhale 0 inspiration expiration Time → Incomplete exhalation 0 inspiration expiration Time → Expiratory flow reaches zero before the next breath. Flow is still expiratory when the next inspiration starts. Air remains trapped End-expiratory lung volume can rise. Intrinsic PEEP Alveolar pressure stays above set external PEEP. Circulation may fall Venous return and RV ejection can be impaired. The flow pattern suggests incomplete emptying; it does not quantify intrinsic PEEP. Conceptual waveforms • No time or flow scale; no CPR artifact shown. Evaluate other causes of sudden deterioration.

Figure

Expiratory flow that has not returned to zero when inspiration begins suggests incomplete emptying. Continued trapping can increase end-expiratory volume and intrinsic PEEP, impairing circulation. The trace does not measure the amount of intrinsic PEEP.

Sourceshttps://cpr.heart.org/en/resuscitation-science/cpr-and-ecc-guidelines/adult-and-pediatric-special-circumstances-of-resuscitationhttps://resus-first-principles.vercel.app/cases/adult-cardiac-arrest

What remains uncertain: in the arrested patient, the relative weight of these mechanisms usually cannot be measured, and more than one is often present. The timing, arrest within minutes of the tube, is the strongest clue that the procedure changed the physiology.

Questions for this part (2)

Question 5.1

Prediction

Predict: the patient is intubated and the bag is being squeezed every 2 or 3 seconds to give more oxygen. What will that do to the circulation, and what rate should replace it?1,10

Commit to an answer before revealing.

Reveal answer for Question 5.1

It is roughly 20 to 30 breaths per minute, and it is likely to reduce venous return and the perfusion that compressions create, as well as risking gastric inflation, regurgitation, and aspiration. With an advanced airway, the rate is 1 breath every 6 seconds, enough to see the chest rise.

Why

Each breath raises intrathoracic pressure. More breaths per minute keep it raised for more of the time, which tends to reduce venous return. With less blood filling the heart, preload falls and each compression ejects less, and coronary perfusion pressure tends to fall. The guideline names the result as decreased cardiac output.

Assumption

Blood oxygen is not limited by ventilation at the slower rate. During CPR, blood flow is low, so 10 breaths per minute at an adequate tidal volume is usually enough to match it.

Common misconception

The belief that more breaths mean more oxygen delivered. Oxygen delivery depends on blood flow as well as oxygen content, and overventilation lowers the flow. Continued after ROSC, the same excess also lowers PaCO2 and constricts cerebral arterioles.

Question 5.2

Transfer

Transfer: a hypotensive septic patient is intubated after induction and arrests within three minutes. The rhythm is a fast, narrow PEA and the capnography waveform is present. Using the filling and obstruction categories, which causes compete, and what would distinguish them?2,10

Commit to an answer before revealing.

Reveal answer for Question 5.2

Three causes compete. Induction drugs remove sympathetic tone and positive pressure raises right atrial pressure, so a patient short of volume loses venous return; a tension pneumothorax from positive pressure obstructs it; and a severe metabolic acidosis loses its respiratory compensation if the ventilator rate is lower than the patient's own. A present waveform makes esophageal intubation less likely. Unilateral signs and rising airway pressure point to tension, a pre-intubation blood gas and breathing pattern point to acidosis, and the shock state before induction points to filling.

Why

Before intubation, venous return was sustained by vasoconstriction keeping mean systemic filling pressure up and by negative-pressure breathing keeping right atrial pressure low. Venous return is approximately mean systemic filling pressure minus right atrial pressure, divided by the resistance to venous return. Induction lowers filling pressure, and positive pressure raises right atrial pressure. The gradient narrows whenever right atrial pressure rises more than filling pressure; venous resistance does not change the gradient, but a higher resistance lowers the flow a given gradient produces. In a study of 10 anesthetized adults (Jellinek 2000), positive airway pressure during apnea raised both pressures by similar amounts, leaving their difference unchanged, yet stroke volume fell, so the gradient alone did not predict the fall; a higher resistance to venous return or effects on the ventricles must account for it. An underfilled patient has less room for filling pressure to rise, so output can fall below the threshold for a pulse.

Assumption

The tube is in the trachea, which the waveform supports but does not prove if pulmonary blood flow is very low.

Common misconception

The belief that an arrest right after intubation is a coincidence or a drug reaction alone. Its timing is the clue that the procedure changed the physiology.

Principle

Reading the resuscitation2,30,31,27,28,29,4

End-tidal CO2 links ventilation back to circulation.

When an endotracheal tube is used, continuous waveform capnography plus clinical assessment is the most reliable confirmation that it is in the trachea. During CPR, carbon dioxide reaches the lungs only as fast as blood carries it there, so end-tidal CO2 tracks pulmonary blood flow. But it has many determinants: the rate and volume of ventilation, tube position, metabolic production, and drugs such as epinephrine. A change in the number is a prompt to ask which of those changed.

The path the CO2 takes explains why. Carbon dioxide is made in the tissues, as the end product of aerobic metabolism in the mitochondria, and it diffuses from the cells into the capillary blood. Venous blood carries it mostly as bicarbonate, with smaller amounts dissolved in plasma and bound to hemoglobin, back through the right heart and the pulmonary arteries to the pulmonary capillaries. There it diffuses into the alveoli and is breathed out. The capnograph samples the exhaled gas, and the end-tidal value is the partial pressure of CO2, in mm Hg, at the end of exhalation, when the gas leaving the tube comes mostly from the alveoli. It is a partial pressure in gas, not an amount of CO2, not a blood pressure, and not a flow, although during CPR it moves with flow.

Arterial and end-tidal CO2 are related but not the same. PaCO2 is the partial pressure of CO2 in arterial blood; end-tidal CO2 is its partial pressure in exhaled gas. They are close only when the ventilated alveoli are also well perfused. Alveoli that receive gas but little blood, alveolar dead space, add gas with almost no CO2 to the exhaled mixture and dilute it, so end-tidal CO2 falls below PaCO2 and the gap between them widens. During CPR, pulmonary blood flow is low and probably unevenly distributed, so much of the ventilated lung is likely to behave this way, and end-tidal CO2 cannot be read as a stand-in for PaCO2.

That dependence is what makes the number useful during CPR. If metabolic production and ventilation are roughly steady, the main limit on how much CO2 reaches the alveoli is how much blood passes through the lungs, which is the output the compressions are generating. End-tidal CO2 then behaves as a proxy for cardiac output, and its trend is more informative than any single value. Several other inputs move it, and each acts at a different point on the path. Faster or larger breaths wash CO2 out of the alveoli and lower the reading without any change in flow. Sodium bicarbonate generates CO2 as it buffers acid, so the reading can rise after a dose without any improvement in flow. Epinephrine is among the factors the guideline lists; in a human study, end-tidal CO2 fell by a variable amount after a dose, so a fall soon after epinephrine need not mean weaker compressions. A dislodged, kinked, or obstructed tube removes or distorts the gas the capnograph is sampling. And anything that suddenly blocks blood from reaching the lung, such as a tension pneumothorax or a large embolus, lowers the reading by the same route as weak compressions.

A bedside example shows how these compete. With the tube secure and ventilation unchanged, a steady fall over a minute or two after a compressor has been working for a long time points first to fatigue and falling depth. The same fall right after the team speeds up the bag rate points first to washout. The number is identical; the history of what changed is what separates the two. The 2025 guideline notes that values above 10 mm Hg, and ideally above 20 mm Hg, are associated with higher rates of ROSC and may indicate mechanically adequate compressions; that rests on association with ROSC, not on trials of titrating CPR to a value.

Because the number has so many inputs, it is better used as a question than as a verdict. A low or falling value asks first whether the compressions have weakened or the tube has moved, and only later whether the patient can be resuscitated. Even then it should not decide the matter alone: in an intubated adult, failure to exceed 10 mm Hg after 20 minutes of ALS may be one part of a multimodal decision to stop. A sudden rise can accompany ROSC, though no single cutoff proves it, so the rise prompts a pulse check rather than replacing one.

Both of the numbers used during CPR stand in for something that cannot be seen, and they stand in for different things. End-tidal CO2 is a surrogate for pulmonary blood flow, and so for the output the compressions are producing, but only while CO2 production and ventilation are roughly steady and the airway is intact. It stops tracking flow whenever one of those moves: a faster bag rate, a dose of bicarbonate or epinephrine, a displaced tube, or an obstruction between the right heart and the lung. An arterial line answers a different question. It measures pressure at the catheter tip, not flow, and during CPR the value that matters is the relaxation-phase aortic pressure, the inlet side of the coronary gradient in 3.1, where the guideline's view of that number, and its lack of a target, is quoted.

The arterial reading stops tracking coronary perfusion in ways the gradient predicts. It is the upstream pressure only, so without a simultaneous right atrial pressure a respectable value can sit over a narrow gradient. It has to be read in the relaxation phase and against the same zero; the peak pressure during compression is not the pressure the coronary arteries fill from. And because a vasoconstrictor such as epinephrine raises aortic pressure largely by raising peripheral resistance, a rise after a dose says that pressure rose, and with it usually the coronary gradient, not that the output of compressions rose. That is one setting in which the two surrogates can move apart, the arterial pressure rising while end-tidal CO2 falls, and the disagreement is informative rather than an error in either. The line can also show what the eye cannot in the other direction: pressure pulses with an organized rhythm and no palpable pulse, the pseudo-PEA described in 4.1.

After ROSC both numbers change meaning. The heart is making the pressure again, and the arterial value of interest becomes mean arterial pressure; the line gives a beat-to-beat check on the floor of 65 mm Hg set out in the post-ROSC targets, an early warning when shock returns, and access for the blood gases that answer the PaCO2 question end-tidal CO2 cannot. End-tidal CO2 still rises and falls with pulmonary blood flow, but with the heart ejecting, flow is no longer the main thing it is asked about, and its use shifts to ventilation, where dead space can make it read below PaCO2 by a variable amount.

A capnography change is a questionCO2 production, pulmonary transport, and excretion feed into measured end-tidal CO2. A sudden fall has competing flow, ventilation, airway, and sampling explanations. A sustained rise can accompany ROSC. Persistently low readings require context rather than an isolated stopping decision. RESUS FIRST PRINCIPLES / FIGURE 05 A capnography change is a question Section VI • Interpret the signal before assigning the cause CO₂ production Metabolism and CO₂ stores CO₂ transport Pulmonary blood flow and perfusion distribution CO₂ excretion Alveolar ventilation and airway / sampling Measured end-tidal CO₂ CHANGE OBSERVED COMPETING EXPLANATIONS TO ASSESS Sudden fall Reduced pulmonary flow; weaker compressions; more ventilation; tube, circuit, or sampling problem. Sustained rise ROSC is possible. Correlate with rhythm and evidence of circulation; altered ventilation can also raise the value. Persistently low Check CPR, airway, ventilation, and clinical context. The value alone is not a stopping rule. Drug effects, including epinephrine, complicate the inference from a trend to flow. Interpretive framework • ETCO₂ is not arterial PaCO₂ and is not a direct cardiac-output measurement.

Figure

Interpret a change in end-tidal CO2 by checking the determinants that could have changed: production, transport, ventilation, and measurement. A rise can suggest ROSC; a low value alone does not establish futility.

Sourceshttps://cpr.heart.org/en/resuscitation-science/cpr-and-ecc-guidelines/adult-advanced-life-support

Questions for this part (3)

Question 6.1

Prediction

Predict: in PEA with an advanced airway, end-tidal CO2 has held near 25 mm Hg for several minutes with the same ventilation rate. It suddenly drops to 8 mm Hg. Name the competing explanations, and the order in which you test them.2,3

Commit to an answer before revealing.

Reveal answer for Question 6.1

With ventilation unchanged, a sudden fall means less CO2 is reaching the exhaled gas. The quickest explanations to test are a displaced or obstructed tube and a fall in compression quality. If both are excluded, a new obstruction to pulmonary blood flow, such as a tension pneumothorax, becomes more likely.

Why

End-tidal CO2 needs blood to carry CO2 to ventilated lung and a patent airway to carry it out. A dislodged tube removes the second; a tired compressor, a change of hands, or a pause reduces the first; a tension pneumothorax or a new embolus blocks blood from reaching the lung. Each of these can produce the same number, so the number tells you to look, not where.

Assumption

Ventilation really was constant, and no drug was just given. A recent dose of epinephrine can change the reading by itself, which makes a fall just after a dose weaker evidence of lost flow.

Common misconception

The belief that a falling end-tidal CO2 is a prognosis. Here it is a signal that something changed, and several of the candidates are quickly correctable.

Question 6.2

Transfer

Transfer: end-tidal CO2 has fallen from 18 mm Hg to 8 mm Hg, and the team starts discussing whether to stop. What could have changed, and what do you check first?2

Commit to an answer before revealing.

Reveal answer for Question 6.2

Check CPR quality and airway position first: rate, depth, recoil, interruptions, and whether the tube is still in the trachea. A falling end-tidal CO2 is a signal about blood flow or ventilation, not a standalone reason to stop.

Why

With steady ventilation, end-tidal CO2 during CPR tracks pulmonary blood flow. A fall often means the compressions are moving less blood, often from fatigue, or the airway has moved. A sudden increase in ventilation rate can also lower it by washing CO2 out faster.

Assumption

Ventilation has been steady. If the ventilation rate changed, the number partly reflects that, not blood flow.

Common misconception

Treating the number as a prognosis. The guidelines say end-tidal CO2 is not used in isolation to end a resuscitation. Only in an intubated patient, and only after 20 minutes of ALS, may failure to exceed 10 mm Hg be considered as one element among others.

Question 6.3

Evidence boundary

Evidence boundary: a minute after epinephrine, end-tidal CO2 falls even though nothing else has changed. Why shouldn't you read that change as a direct measure of better or worse blood flow?2,29

Commit to an answer before revealing.

Reveal answer for Question 6.3

Because epinephrine is among the factors the 2025 guideline lists as affecting end-tidal CO2, so the reading can move after a dose for reasons other than a change in blood flow. A fall after a dose should not, on its own, be read as a loss of flow. The number has several determinants, and a drug can move it in the opposite direction from the quantity you care about.

Why

End-tidal CO2 depends on how much CO2 reaches the lungs and how well the ventilated areas of the lung are perfused. Epinephrine raises aortic pressure, which helps coronary perfusion, but the guideline also lists it among the factors that affect end-tidal CO2 and in a prehospital human study the reading fell by a variable amount after a dose. After a dose, the reading can therefore move independently of cardiac perfusion.

Assumption

Ventilation and compression quality were truly unchanged across that minute.

Common misconception

The belief that end-tidal CO2 is a flow meter. It is a surrogate, useful for trends when other variables are stable, and least reliable when several are changing at once.

Principle

The Hs and Ts are ways the circulation fails5,2,3

Not every arrest is a primary electrical failure.

When the rhythm is PEA or asystole, the heart is often unable to produce output because something upstream or around it has failed. The 2025 adult algorithm keeps one reversible-cause list: hypovolemia, hypoxia, hydrogen ion (acidosis), hypo- or hyperkalemia, hypothermia, tension pneumothorax, cardiac tamponade, toxins, pulmonary thrombosis, and coronary thrombosis.

The list is easier to use when it is grouped by physiology. Some causes leave the heart with too little to pump: hypovolemia, and the loss of venous return from tension pneumothorax. Some stop the heart from filling or emptying: tamponade and massive pulmonary embolism. Some starve or poison the myocardium itself: hypoxia, coronary thrombosis, acidosis, potassium disturbance, hypothermia, and toxins. Each group predicts what will and won't help.

The first group fails before blood reaches the heart. In hypovolemia the deficit is volume: blood or fluid has left the vessels, the stressed volume that stretches the veins shrinks, and mean systemic filling pressure falls toward right atrial pressure, so the gradient that drives venous return narrows from the upstream end. In tension pneumothorax the volume may be normal, but air trapped in one pleural space raises the pressure around the heart and great veins, and right atrial pressure rises toward filling pressure, so the same gradient narrows from the downstream end. Both leave the ventricles underfilled, and an underfilled ventricle ejects little whatever its rhythm or contractility. The prediction changes with what is added: a patient who is both bleeding and under tension has the gradient attacked from both sides, and treating one leaves it narrowed. During resuscitation the meaning is that compressions can only move the blood that is in the chest, and the treatment is to restore volume or release the trapped air, as the cause entries below describe.

The second group fails at the heart itself, in the space around it or the vessel leaving it. In tamponade, fluid in the pericardium raises the pressure outside the chambers; the right atrial reading is high, but the transmural pressure that distends the chambers is small, so the heart cannot expand to receive blood. In massive pulmonary embolism the obstruction lies downstream of the right ventricle: clot in the pulmonary arteries raises the pressure the right ventricle must eject against, the right ventricle dilates and fails, and little blood crosses the lungs to fill the left heart. The two can look alike at the bedside, with distended neck veins and a fast, narrow PEA, because both raise right atrial pressure while the left ventricle is starved of volume. A high right atrial pressure in either condition also raises the outlet pressure of the coronary bed described in 3.1, so relaxation-phase aortic pressure buys less coronary perfusion. Compressions and vasopressors push against the obstruction rather than removing it, which is why drainage, decompression, or reperfusion of the pulmonary arteries is the treatment that changes the physics.

The third group leaves filling intact and injures the pump or its electrical control. Hypoxia lowers arterial oxygen content, so the same flow delivers less oxygen to the myocardium; coronary thrombosis stops flow to a region of muscle; acidosis, potassium disturbance, hypothermia, and many toxins alter the ion channels, the calcium handling, or the energy supply on which depolarization and contraction depend. Here the distinction drawn in 4.1 matters: the heart may still depolarize in an organized way while contracting weakly, or it may be driven into VF. A rhythm can suggest one of these causes, but it does not diagnose it, because the same rhythm arises from several and one cause can produce several rhythms over time. What changes the prediction is duration and combination, and a heart that has been ischemic or acidotic for longer is likely to respond less to correction. During resuscitation, the treatment is specific to the cause: oxygen and ventilation for hypoxia, correction of potassium, rewarming, an antidote or targeted drug for a toxin, and reperfusion for coronary occlusion.

This is why compressions and epinephrine alone often fail in these arrests. Compressions do little to fill an empty ventricle, and they do not drain a tamponade, decompress a tension pneumothorax, or open an occluded coronary artery. Epinephrine raises arterial tone, but it does not remove an obstruction. The cause has to be found and treated while compressions continue. Point-of-care ultrasound can be used by an experienced operator to look for a reversible cause when it does not interrupt CPR, though its usefulness during arrest is not well established.

Calcium and sodium bicarbonate show how a plausible mechanism can outrun the evidence. Undifferentiated arrest means the cause is unknown, not that no cause is present, and four different statements need to be kept apart here. Routine use is not recommended: giving either drug to every arrest, without a specific indication, has not improved survival in randomized and registry evidence, and routine calcium has a signal toward harm. Benefit is uncertain in some specific settings: in arrest suspected to be from hyperkalemia, the benefit of intravenous calcium and of intravenous sodium bicarbonate is not well established. A mechanism being plausible is not the same as it being established in this patient, which usually cannot be confirmed during CPR. And none of this makes either drug contraindicated; it makes them targeted rather than default. Calcium is reasonable for life-threatening calcium-channel blocker poisoning and for arrest in a pregnant patient receiving intravenous magnesium. Sodium bicarbonate should be used for life-threatening tricyclic antidepressant cardiotoxicity, and it is reasonable for life-threatening cardiotoxicity from sodium-channel blockers other than tricyclic and tetracyclic antidepressants. A long resuscitation is not, by itself, a reason to give either drug.

The groups describe mechanisms, not patients, and the causes interact. Hypovolemia worsens the acidosis that follows low flow, acidosis blunts the response to catecholamines, hypoxia and acidosis together depress contractility, and positive-pressure ventilation can turn a marginal venous return into an inadequate one. A patient may carry one cause from each group at once. The practical consequence is to keep looking after the first cause is found and treated, and to judge each intervention by whether the circulation changes rather than by whether the explanation seemed complete. This is reasoning from physiology; the guideline supports searching for and treating reversible causes during CPR, but it does not rank them or show that this grouping improves survival.

The limit of the model: during arrest you often cannot confirm the cause, and several can coexist. The categories help you decide what to look for and what to treat on suspicion, not prove the diagnosis.

Schematic, not measured data. Reversible causes grouped by the mechanism they disrupt: preload, pump, obstruction (filling or outflow), oxygenation, and electrical substrate. Each name links to that cause. A repeated name is the same cause under more than one mechanism. The drawing ranks none of them and shows no measured weight.Schematic, not measured data. Each reversible cause is drawn under each mechanism it disrupts, and each name links to that cause. Preload shows Hypovolemia and Tension pneumothorax. Pump shows Hydrogen ion (acidosis), Hypothermia, Toxins, and Coronary thrombosis. Obstruction (filling or outflow) shows Tension pneumothorax, Cardiac tamponade, and Pulmonary thrombosis (massive embolism). Oxygenation shows Hypoxia and Toxins. Electrical substrate shows Hydrogen ion (acidosis), Hyperkalemia, Hypokalemia, Hypothermia, Toxins, and Coronary thrombosis. A name is repeated when the cause is drawn under more than one mechanism. The drawing ranks none of them and shows no measured weight. Vasodilation, as with some toxins and acidosis, is not drawn.Schematic, not measured dataMechanismsReversible causesEach name links to that cause.PreloadHypovolemiaTension pneumothoraxPumpHydrogen ion (acidosis)HypothermiaToxinsCoronary thrombosisObstruction(filling or outflow)Tension pneumothoraxCardiac tamponadePulmonary thrombosis(massive embolism)OxygenationHypoxiaToxinsElectrical substrateHydrogen ion (acidosis)HyperkalemiaHypokalemiaHypothermiaToxinsCoronary thrombosisSchematic, not measured data. Reversible causes grouped by the mechanism they disrupt: preload, pump, obstruction (filling or outflow), oxygenation, and electrical substrate. Each name links to that cause. A repeated name is the same cause under more than one mechanism. The drawing ranks none of them and shows no measured weight.Schematic, not measured data. Each reversible cause is drawn under each mechanism it disrupts, and each name links to that cause. Preload shows Hypovolemia and Tension pneumothorax. Pump shows Hydrogen ion (acidosis), Hypothermia, Toxins, and Coronary thrombosis. Obstruction (filling or outflow) shows Tension pneumothorax, Cardiac tamponade, and Pulmonary thrombosis (massive embolism). Oxygenation shows Hypoxia and Toxins. Electrical substrate shows Hydrogen ion (acidosis), Hyperkalemia, Hypokalemia, Hypothermia, Toxins, and Coronary thrombosis. A name is repeated when the cause is drawn under more than one mechanism. The drawing ranks none of them and shows no measured weight. Vasodilation, as with some toxins and acidosis, is not drawn.Schematic, not measured dataMechanismsReversible causesEach name links to that cause.PreloadHypovolemiaTension pneumothoraxPumpHydrogen ion (acidosis)HypothermiaToxinsCoronary thrombosisObstruction(filling or outflow)Tension pneumothoraxCardiac tamponadePulmonary thrombosis(massive embolism)OxygenationHypoxiaToxinsElectrical substrateHydrogen ion (acidosis)HyperkalemiaHypokalemiaHypothermiaToxinsCoronary thrombosis

Figure

Schematic, not measured data. Each reversible cause is drawn under each mechanism it disrupts, and each name links to that cause. Preload shows Hypovolemia and Tension pneumothorax. Pump shows Hydrogen ion (acidosis), Hypothermia, Toxins, and Coronary thrombosis. Obstruction (filling or outflow) shows Tension pneumothorax, Cardiac tamponade, and Pulmonary thrombosis (massive embolism). Oxygenation shows Hypoxia and Toxins. Electrical substrate shows Hydrogen ion (acidosis), Hyperkalemia, Hypokalemia, Hypothermia, Toxins, and Coronary thrombosis. A name is repeated when the cause is drawn under more than one mechanism. The drawing ranks none of them and shows no measured weight. Vasodilation, as with some toxins and acidosis, is not drawn.

Filling

Hypovolemia5,2

Failure

The ventricle has too little blood to eject. Mean systemic filling pressure depends on how much blood is stretching the veins, so losing volume lowers the pressure that drives blood back to the heart, and venous return falls even before the heart itself is injured.

Rhythm

An empty heart still conducts. Before arrest the sinus node is driven hard by catecholamines, so the typical picture is a narrow-complex tachycardia that becomes PEA with a fast, narrow rhythm once stroke volume is too small to make a palpable pulse. Early in this state the ventricle may still be contracting vigorously around very little blood, which is why some of these patients have cardiac motion on ultrasound without a pulse.

The rule of thumb breaks when the arrest has gone on long enough for acidosis and ischemia to slow and widen the complex, and in patients on beta blockers or with conduction disease who cannot mount a tachycardia in the first place.

Causal chain

Blood loss or fluid loss lowers the volume stretching the venous system. Mean systemic filling pressure falls toward right atrial pressure, the gradient for venous return narrows, and the ventricle fills less on each beat. Stroke volume falls, the body compensates with heart rate and vasoconstriction, and when compensation is exhausted, aortic pressure falls below what is needed to perfuse the coronary arteries. The myocardium then becomes ischemic, and the arrest that began as an empty heart becomes an injured one.

Compressions

Compressions squeeze whatever blood is in the chest. With little blood in the heart and great veins, each compression ejects a small volume, and the release has little venous return to refill from. Aortic pressure during compression tends to stay low, so coronary perfusion pressure tends to stay low even when depth and recoil are good.

Fix

Volume, and in hemorrhage, blood and control of the bleeding, restores the quantity that was missing. Raising the circulating volume raises mean systemic filling pressure, which widens the gradient for venous return, so the heart refills between beats or between compressions. Vasopressors can raise filling pressure modestly by tightening the veins, but they cannot replace volume that has left the circulation.

Bedside

The history usually makes the diagnosis: trauma, gastrointestinal bleeding, a ruptured aneurysm or ectopic pregnancy, or severe vomiting, diarrhea, or diuresis. Flat neck veins and a pale patient support it. On ultrasound a small, hyperdynamic ventricle with a collapsing inferior vena cava fits, though during CPR the vena cava is hard to interpret and a small ventricle can also be seen with obstruction downstream of it.

Mimics

Tension pneumothorax and tamponade also reduce filling and produce a fast, narrow PEA, but they raise venous pressure rather than lowering it, so distended neck veins point away from simple hypovolemia. Vasodilatory states such as anaphylaxis or sepsis lower filling pressure by enlarging the venous space rather than by losing blood, and behave like hypovolemia at the bedside.

Limits

You usually cannot measure the deficit during CPR. Ultrasound findings of an empty heart are suggestive rather than diagnostic, and their usefulness during arrest is not well established. In traumatic arrest, hemorrhage control and volume matter more than drugs, but the details of traumatic arrest management sit outside this case.

Examples

  1. IExample

    Vignette

    A 68-year-old with melena and dizziness becomes unresponsive in triage. The monitor shows a narrow rhythm at 130 per minute with no pulse.

    Reasoning

    A fast, narrow PEA after visible blood loss points to an empty heart. Compressions continue, but the decisive treatment is volume and blood through large-bore access.

  2. IIExample

    Vignette

    A 29-year-old collapses at home after a day of lower abdominal pain. EMS finds PEA at a rapid narrow rate; her abdomen is distended.

    Reasoning

    Intra-abdominal hemorrhage, such as a ruptured ectopic pregnancy, empties the venous reservoir. Epinephrine cannot replace the lost volume; volume, blood, and definitive surgical control address the failure.

  3. IIIExample

    Vignette

    A motorcyclist with a pelvic fracture and absent breath sounds on the right arrests en route. The rhythm is narrow and fast; the neck veins are flat despite the chest finding.

    Reasoning

    Two filling failures can coexist. Blood loss lowers filling pressure, and a tension pneumothorax raises intrathoracic pressure; flat neck veins here reflect how little volume is left. Decompress the chest and give blood, because treating only one leaves the gradient for venous return closed.

Oxygen content

Hypoxia1,3

Failure

The blood still moves, but it carries too little oxygen. The myocardium depends on a continuous oxygen supply, so falling arterial oxygen content starves it and the conducting system until they fail.

Rhythm

Hypoxic arrest classically progresses through bradycardia. The myocardium and the sinus node slow as oxygen falls, so the terminal rhythm is often a slow PEA that degrades to asystole, sometimes preceded by a period of tachycardia while catecholamines still drive the heart.

This does not fit the narrow-fast versus wide-slow rule neatly. The complex may be narrow at first and widen only as acidosis and ischemia accumulate, and a hypoxic patient with underlying heart disease can arrest in VF instead.

Causal chain

Airway obstruction, apnea, drowning, or failure of gas exchange lowers alveolar and then arterial oxygen. Oxygen delivery to the myocardium falls, aerobic metabolism fails, and contractility and conduction weaken. The heart slows, cardiac output falls further, and the decline in delivery accelerates until the circulation stops.

Compressions

Compressions can move blood, but if that blood is desaturated they deliver very little oxygen. In asphyxial arrest, oxygen stores were depleted before the circulation stopped, so compression-only CPR moves blood that has nothing to give.

Fix

Opening the airway and ventilating with oxygen restores arterial oxygen content, so the same compression-generated flow now delivers oxygen to the myocardium. If the heart has not been without oxygen for long, restoring content alone may be enough for the slowing heart to recover.

Bedside

The setting usually tells you: choking, drowning, opioid overdose, severe asthma or COPD, or a failed airway. Cyanosis, a slow rhythm before arrest, and a history of respiratory distress support it. After intubation, waveform capnography confirms the tube; a tube in the esophagus produces no sustained CO2 waveform.

Mimics

Tension pneumothorax and a misplaced or obstructed tube produce hypoxia and also impair circulation. Severe acidosis and hyperkalemia can also slow the heart before arrest.

Limits

Pulse oximetry is unreliable during CPR, so arterial oxygenation usually cannot be measured until circulation returns. The guideline emphasis on breaths in drowning reflects the hypoxic mechanism; the evidence comes mainly from observational studies.

Examples

  1. IExample

    Vignette

    A 40-year-old is pulled from a lake after several minutes underwater. He is pulseless and the first rhythm is asystole.

    Reasoning

    Drowning arrest is usually hypoxic. Breaths matter here more than in a sudden cardiac arrest, because the blood was desaturated before it stopped moving.

  2. IIExample

    Vignette

    A 25-year-old is found apneic with pinpoint pupils, then loses her pulse; the rhythm is a slow PEA.

    Reasoning

    Opioid-induced apnea causes hypoxic arrest. Ventilation and compressions come first; an opioid antagonist may be reasonable in cardiac arrest with suspected opioid overdose if it does not interrupt high-quality CPR. No trial has shown that it restarts a heart that has already stopped from hypoxia.

  3. IIIExample

    Vignette

    Minutes after intubation for pneumonia, a patient's saturation falls, the heart slows, and the pulse is lost. The capnography waveform is flat.

    Reasoning

    A flat waveform after intubation suggests the tube is not in the trachea, or there is no pulmonary blood flow. Check tube position first, because a misplaced tube makes hypoxia the cause and is quickly corrected.

Contractility and electrical

Hydrogen ion (acidosis)2,3,11

Failure

Severe acidemia weakens the myocardium and the vessels. It depresses contractility, blunts the response of the heart and vessels to catecholamines, and favors arrhythmia, so the pump and the pressure it works against both fail.

Rhythm

Metabolic arrests tend toward a slow, wide-complex PEA, because acidosis and the potassium shifts that accompany it slow conduction through the myocardium.

The rule breaks often. Acidosis is usually a consequence of another failure, such as shock, hypoxia, or a toxin, and the rhythm reflects that primary failure. A patient with diabetic ketoacidosis may arrest with a narrow, fast PEA while volume depletion, acidemia, and a potassium disturbance are all contributing.

Causal chain

A primary metabolic insult, such as ketoacidosis, sepsis, renal failure, or a toxic alcohol, or a respiratory one, such as hypoventilation, lowers the pH. Contractility falls, vascular tone falls, and the response to catecholamines weakens. Cardiac output and blood pressure fall, tissue perfusion worsens, and more lactate is produced. The loop closes until the circulation fails.

Compressions

Compressions are generating flow through a vascular bed with poor tone and into a myocardium that is less responsive to the epinephrine meant to augment the gradient. The acidosis itself does not stop compressions from moving blood, but it reduces what they and the drugs achieve.

Fix

The durable fix is to treat the source: restore perfusion, ventilate a patient whose acidosis is respiratory, treat the toxin or the ketoacidosis. Sodium bicarbonate raises pH chemically, but it generates CO2 that must be ventilated away, and routine use in cardiac arrest is not recommended. It is a targeted drug for specific toxic causes, not a general correction of acidosis.

Bedside

History of renal failure, diabetes, sepsis, toxic ingestion, or prolonged shock raises suspicion. Kussmaul breathing before arrest suggests a metabolic acidosis with respiratory compensation. A blood gas during CPR shows severe acidemia in most prolonged arrests regardless of cause, so the number is less diagnostic than the history.

Mimics

Almost every prolonged arrest becomes acidotic. Hyperkalemia often travels with acidosis and produces the same wide, slow rhythm.

Limits

During CPR you usually cannot separate acidosis that caused the arrest from acidosis the arrest caused. A severely acidemic patient with a compensating respiratory drive can deteriorate if intubated and ventilated at a lower minute ventilation than they were generating; this is physiologically reasonable but has not been tested in trials.

Examples

  1. IExample

    Vignette

    A 22-year-old with type 1 diabetes, vomiting for two days, arrives breathing deep and fast, then arrests. The rhythm is a fast, narrow PEA. The glucose is very high, and the first potassium was high despite total-body depletion.

    Reasoning

    Three causes overlap and interact. Osmotic diuresis and vomiting have depleted volume, insulin deficiency and acidemia have moved potassium out of cells while total-body stores fell, and acidemia has weakened the myocardium. The narrow, fast rhythm does not settle which dominates. A blood-gas potassium and pH, the ECG, and a look at ventricular filling separate them better, and during arrest, volume, potassium, and acid-base problems are addressed in parallel while CPR continues; outside arrest, the consensus sequence still applies, with fluids first and insulin delayed until potassium is above 3.5 mmol/L.

  2. IIExample

    Vignette

    A patient with severe salicylate or metabolic acidosis, compensating by breathing very fast, arrests minutes after intubation and ventilation at a standard rate.

    Reasoning

    The ventilator removed the respiratory compensation, so CO2 rose and pH fell abruptly. Both the acidosis and the toxin are in play; the ventilation rate before and after intubation is the key piece of history.

Contractility and electrical

Hyperkalemia3,2

Failure

A high extracellular potassium lowers the resting membrane potential of cardiac cells toward threshold. Partly depolarized cells inactivate their fast sodium channels, so the action potential rises more slowly, conduction slows, and eventually the myocardium can no longer propagate an impulse.

Rhythm

This is the classic wide, slow pattern. Conduction slows across atria and ventricles, the QRS widens, and before arrest the tracing may approach a sine wave. The arrest rhythm is often a slow, wide PEA or asystole, though VF can occur.

The characteristic ECG changes have low sensitivity and specificity. Some patients arrest with only modest QRS widening, and acidosis or sodium-channel-blocking drugs can produce the same wide, slow picture.

Causal chain

Renal failure, potassium-sparing drugs, tissue breakdown, or a shift of potassium out of cells raises extracellular potassium. The resting membrane potential becomes less negative, sodium channels inactivate, conduction slows and blocks, and contraction fails because the electrical signal can no longer spread.

Compressions

Compressions perfuse a myocardium that cannot conduct. They keep the cells alive while the electrical problem is treated, but they do nothing to restore conduction.

Fix

Calcium raises the threshold potential, widening the gap between the resting potential and threshold again. It stabilizes the membrane without lowering potassium at all, which is why its effect is temporary. Insulin with glucose and sodium bicarbonate shift potassium into cells, and only removal, usually by dialysis, lowers total-body potassium. In arrest suspected to be from hyperkalemia, the effectiveness of intravenous calcium, intravenous sodium bicarbonate, and insulin with glucose is each not well established in the 2025 guidance, and inhaled beta-2 agonists are not recommended.

Bedside

Dialysis patients who missed a session, patients with acute kidney injury, crush injury, or those taking potassium-raising drugs. A pre-arrest ECG with peaked T waves, a widened QRS, or a sine wave supports it. A point-of-care potassium can confirm it quickly where available.

Mimics

Acidosis shifts potassium out of cells during any prolonged arrest, so a high potassium measured late in CPR does not prove hyperkalemia caused the arrest. Sodium-channel-blocker poisoning widens the QRS by a different mechanism.

Limits

The physiology of membrane stabilization is well established, but evidence that calcium improves survival in hyperkalemic arrest is thin, largely old experimental and case data. Treat on reasonable suspicion while knowing that the benefit during arrest is uncertain.

Examples

  1. IExample

    Vignette

    A dialysis patient who missed two sessions is bradycardic with a wide QRS on arrival, then loses her pulse. The rhythm is a slow, wide PEA.

    Reasoning

    Missed dialysis plus a wide, slow rhythm makes hyperkalemia the leading cause. Calcium may stabilize the membrane while potassium is shifted and then removed, though its benefit during arrest is not well established.

  2. IIExample

    Vignette

    A worker trapped under a collapsed wall for hours arrests shortly after the load is lifted. The rhythm is wide and slow.

    Reasoning

    Release of a crushed limb returns potassium and acid from damaged muscle into the circulation. The timing, arrest soon after release, is the clue; hypovolemia from third spacing may coexist.

Contractility and electrical

Hypokalemia5,2

Failure

A low extracellular potassium makes the resting membrane more negative but delays repolarization, prolonging the action potential and favoring early afterdepolarizations and triggered activity. The heart is electrically unstable rather than unexcitable.

Rhythm

Hypokalemia tends toward ventricular arrhythmias, including torsades de pointes and VF, rather than the slow, wide PEA of hyperkalemia. Prolonged QT and prominent U waves before arrest are the warning.

Severe hypokalemia can also cause profound weakness, including of respiratory muscles, and an arrest that is partly hypoxic may not follow this pattern.

Causal chain

Losses from diuretics, vomiting, diarrhea, or a shift into cells from insulin or catecholamines lower extracellular potassium. Repolarization is delayed, the QT lengthens, and afterdepolarizations trigger ventricular ectopy that can degenerate into VF.

Compressions

Compressions supply flow during VF, but they do not correct the substrate. A shock may terminate VF, only for it to recur while the potassium remains low.

Fix

Replacing potassium restores normal repolarization. Magnesium deficiency often travels with hypokalemia and impairs its correction. Neither has a defined dose in the 2025 adult arrest algorithm, so specific replacement regimens belong to local protocol.

Bedside

Heavy diuretic use, vomiting, diarrhea, alcohol use disorder, or recent insulin treatment for DKA. A pre-arrest ECG with QT prolongation and U waves supports it.

Mimics

Drug-induced QT prolongation and hypomagnesemia produce the same torsades-prone substrate.

Limits

Potassium replacement during CPR has not been tested in trials, and the measured value can be distorted by shifts during arrest. The mechanism is sound; the timing and amount of intra-arrest replacement are not established.

Examples

  1. IExample

    Vignette

    A patient on high-dose diuretics develops recurrent VF that terminates with each shock and returns within a minute.

    Reasoning

    VF that keeps recurring after successful shocks suggests a persistent substrate. A low potassium or magnesium is one candidate, alongside ischemia, and needs correcting for the shocks to hold.

  2. IIExample

    Vignette

    Six hours into insulin treatment for DKA, a patient whose potassium was not rechecked develops torsades and then VF.

    Reasoning

    Insulin shifts potassium into cells. A patient who was depleted overall despite a high initial value can become severely hypokalemic during treatment.

Contractility and electrical

Hypothermia3

Failure

Cold slows every process in the heart: conduction, contraction, and the metabolic rate of the myocardium itself. Below a point the myocardium becomes irritable and prone to VF, and further cooling leads to asystole.

Rhythm

Progressive cooling produces bradycardia, prolonged intervals, and sometimes a J (Osborn) wave, then atrial fibrillation, VF, and asystole. The slow, wide pattern fits.

The pattern breaks because rough handling or rewarming can trigger VF at any stage, and a cold patient can have a pulse so slow and faint that it is missed.

Causal chain

Environmental exposure, immersion, or impaired thermoregulation lowers core temperature. Conduction and contraction slow, the myocardium becomes irritable, and eventually VF or asystole ends the circulation. The same cold lowers the brain's oxygen demand, which is why some patients survive prolonged arrest neurologically intact.

Compressions

The cold chest wall is stiff and compressions are harder to deliver effectively. A cold myocardium may respond poorly to shocks and drugs until it is rewarmed.

Fix

Rewarming restores the temperature-dependent function of the conducting system and myocardium. Patients should be rewarmed during resuscitation, and extracorporeal life support can be used where available, because it rewarms the core while supporting the circulation.

Bedside

The setting, cold exposure or immersion, and a low core temperature measured with a low-reading thermometer. Pulse and breathing should be checked carefully, because both may be very slow.

Mimics

Hypothyroidism, sepsis, and intoxication cause hypothermia that is a marker of another illness rather than the primary cause of arrest.

Limits

Patients with environmental hypothermia may survive with good neurological outcome after prolonged arrest, which makes the usual cues for stopping unreliable. The specifics of drug and shock timing in severe hypothermia rest on weak evidence; follow Part 10 and local protocol rather than a rule derived here.

Examples

  1. IExample

    Vignette

    A skier buried in snow for over an hour is extracted pulseless with a core temperature well below normal. The rhythm is VF.

    Reasoning

    A cold heart may resist shocks until rewarmed, and a cold brain may tolerate a long low-flow period. Continue resuscitation, rewarm, and transfer to a center with extracorporeal support where available.

  2. IIExample

    Vignette

    A 30-year-old is pulled from icy water after a long submersion. She is cold and asystolic.

    Reasoning

    Two causes coexist: drowning makes the arrest hypoxic, and cold may protect the brain. Ventilation with oxygen and rewarming are both part of the treatment.

Obstruction

Tension pneumothorax5,3

Failure

Air trapped under pressure in one pleural space raises intrathoracic pressure and compresses the great veins and the heart. Physically this is a filling failure caused by an obstruction outside the heart: right atrial pressure rises toward mean systemic filling pressure, so the gradient for venous return narrows and can close.

Rhythm

Like the empty heart, a tension pneumothorax typically produces a fast, narrow PEA. The ventricle is underfilled but electrically healthy at first.

Late, hypoxia and acidosis slow and widen the rhythm. In a ventilated patient, rising airway pressures and falling saturation may precede the change in rhythm.

Causal chain

A one-way leak lets air enter the pleural space without escaping. Pressure builds, the mediastinum shifts, the vena cava and right atrium are compressed, and venous return falls. Cardiac output falls while gas exchange worsens on the affected side, and the combination of obstruction and hypoxia ends the circulation.

Compressions

Compressions push on a chest already under raised pressure. On release, the trapped air keeps intrathoracic and right atrial pressure high, so right atrial pressure does not fall far enough below mean systemic filling pressure for blood to return; the heart refills poorly, and positive-pressure ventilation worsens the tension with every breath.

Fix

Decompression lets the trapped air escape, lowering intrathoracic and right atrial pressure. The gradient for venous return reopens, the heart refills, and output can recover within a few beats if the myocardium is not yet injured.

Bedside

Trauma, positive-pressure ventilation, central line placement, or severe asthma or COPD. Absent breath sounds on one side, rising peak airway pressures, distended neck veins, and tracheal deviation are classic but inconsistent. In life-threatening asthma, sudden high inspiratory pressures or difficulty ventilating should prompt evaluation for tension pneumothorax.

Mimics

Mainstem intubation produces unilateral absent breath sounds without tension. Dynamic hyperinflation in asthma raises intrathoracic pressure and reduces venous return by the same mechanism, on both sides.

Limits

Clinical signs are unreliable in a noisy resuscitation, and ultrasound for absent lung sliding is helpful in experienced hands but has not been established as accurate during arrest. Needle decompression can fail if the needle is too short or kinks.

Examples

  1. IExample

    Vignette

    A patient with COPD arrests three minutes after intubation. Peak pressures are high, the left chest is silent, and the rhythm is a fast, narrow PEA.

    Reasoning

    Positive pressure into fragile lungs can create a tension pneumothorax. The timing after intubation and the high airway pressures point to obstruction of venous return.

  2. IIExample

    Vignette

    A patient with severe asthma, bagged rapidly after intubation, loses his pulse. Breath sounds are equal but very quiet.

    Reasoning

    Breath stacking raises intrathoracic pressure on both sides and reduces venous return by the same mechanism as a tension pneumothorax. A brief disconnection from the bag to allow exhalation may relieve it, while a true tension pneumothorax remains possible.

Obstruction

Cardiac tamponade5,3

Failure

Fluid in the pericardium raises pressure around the heart. Because the pericardium cannot stretch acutely, the chambers cannot expand to fill, so the heart is physically prevented from receiving blood. A catheter in the right atrium reads a high pressure, but that reading is intracavitary; the pressure that distends the chamber, inside pressure minus pericardial pressure, is small. A high right atrial reading here therefore coexists with an underfilled heart, and it also raises the back pressure that venous return must overcome.

Rhythm

Tamponade typically produces a fast, narrow rhythm that becomes PEA as filling fails, with electrical alternans sometimes visible before arrest.

After cardiac surgery, trauma to the heart, or in a patient with conduction disease, the rhythm may not fit, and long arrests widen it.

Causal chain

Blood or fluid accumulates in the pericardial sac. Pericardial pressure rises until it approaches the filling pressures of the right heart. The right atrium and ventricle collapse during diastole, filling falls, stroke volume falls, and output fails despite an electrically intact heart.

Compressions

Compressions squeeze a heart that cannot refill on release, because the pericardial pressure holds the chambers small. External compression may also raise pericardial pressure further.

Fix

Draining the pericardium, by pericardiocentesis or by opening the chest when that is possible and appropriate, lowers pericardial pressure below filling pressure again. The chambers expand, fill, and eject, often immediately.

Bedside

Penetrating chest trauma, recent cardiac surgery or catheter procedures, malignancy, renal failure, or aortic dissection. Distended neck veins with a fast, narrow PEA suggest it. A pericardial effusion with a collapsing right heart on ultrasound supports it, though an effusion alone does not prove tamponade.

Mimics

Tension pneumothorax and massive pulmonary embolism also produce distended neck veins with a narrow, fast PEA. Epicardial fat can look like an effusion.

Limits

Ultrasound is the main bedside tool for this cause, but its accuracy during arrest has not been quantified against a reference standard. After cardiac surgery, the guideline supports early resternotomy in an appropriately staffed and equipped ICU.

Examples

  1. IExample

    Vignette

    A young man with a stab wound below the left nipple loses his pulse in the trauma bay. The neck veins are full and the rhythm is narrow and fast.

    Reasoning

    Penetrating trauma to the cardiac box plus distended neck veins points to tamponade. Draining the pericardium, not more epinephrine, reopens filling.

  2. IIExample

    Vignette

    Six hours after bypass surgery, chest tube output stops abruptly, blood pressure falls, and the patient arrests.

    Reasoning

    Clotted drains can let blood accumulate around the heart. Early after cardiac surgery, rapid resternotomy in an equipped ICU addresses both tamponade and bleeding.

Obstruction

Pulmonary thrombosis (massive embolism)3,5

Failure

A large clot blocks the pulmonary arterial outflow. The right ventricle cannot eject enough against the obstruction, so the left heart receives too little blood. The right ventricle dilates and pushes the septum into the left ventricle, worsening left-sided filling further.

Rhythm

Massive embolism typically presents as a fast, narrow PEA, often after a period of sinus tachycardia and hypoxia.

Right ventricular ischemia and hypoxia can slow and widen the rhythm, and a right bundle branch block pattern can appear.

Causal chain

A clot from the deep veins lodges in the main pulmonary arteries. Right ventricular afterload rises abruptly, the right ventricle dilates and fails, left ventricular filling falls, and systemic pressure falls. Right coronary perfusion falls just as right ventricular demand rises, and the right ventricle becomes ischemic.

Compressions

Compressions push blood toward a blocked pulmonary outflow. Little reaches the left heart, so each compression ejects a small volume into the aorta, and coronary perfusion pressure tends to stay low.

Fix

Thrombolysis, or surgical or catheter removal of the clot, reopens the pulmonary outflow so the right ventricle can eject and the left ventricle can fill. Extracorporeal life support can bypass the obstruction while definitive treatment is arranged.

Bedside

Recent surgery, immobility, cancer, prior thrombosis, pregnancy, or a swollen leg; sudden collapse after dyspnea or chest pain. A dilated right ventricle on ultrasound is suggestive.

Mimics

Any prolonged arrest can dilate the right ventricle, because blood pools in the right heart once the circulation stops. Right ventricular infarction and tension pneumothorax can produce similar findings.

Limits

During CPR, pulmonary embolism is usually suspected rather than confirmed. For confirmed embolism, systemic fibrinolysis, surgical embolectomy, and percutaneous mechanical embolectomy are reasonable. For suspected embolism, systemic fibrinolysis may be considered. Extracorporeal life support is reasonable for confirmed or suspected embolism. Fibrinolysis carries a bleeding risk, and the optimal duration of CPR after a systemic fibrinolytic is unclear. Unclear is not the same as short. The trials AHA cites continued CPR for at least 15 or 30 minutes after the drug, and the 2019 ESC guideline advises at least 60 to 90 minutes, so stopping soon after the drug is given is not supported. Right ventricular dilation on ultrasound during arrest is not specific for embolism.

Examples

  1. IExample

    Vignette

    Five days after hip surgery, a patient becomes suddenly breathless and collapses. The rhythm is a fast, narrow PEA; ultrasound shows a very large right ventricle.

    Reasoning

    The history and the dilated right ventricle make pulmonary embolism likely, though RV dilation during arrest is not specific. If embolism is only suspected, systemic fibrinolysis may be considered. When it is confirmed, systemic fibrinolysis, surgical embolectomy, and percutaneous mechanical embolectomy are reasonable. Extracorporeal life support is reasonable for confirmed or suspected embolism. Evidence for fibrinolysis is weaker without confirmation.

  2. IIExample

    Vignette

    A patient admitted with a known deep vein thrombosis has a sudden fall in end-tidal CO2 while still conscious, followed by collapse.

    Reasoning

    A sudden fall in end-tidal CO2 with steady ventilation means less blood is reaching ventilated lung. Before arrest, that fits obstruction of pulmonary blood flow.

Contractility and electrical

Toxins3,2

Failure

Poisons fail the circulation in several ways: by blocking ion channels in the myocardium, by depressing contractility, by dilating vessels, or by stopping breathing. The category is mechanistic rather than single: each toxin needs its own physiology.

Rhythm

Sodium-channel blockers such as tricyclic antidepressants widen the QRS and produce a wide, slow rhythm. Calcium-channel blockers and beta blockers produce bradycardia and conduction block. These fit the slow pattern, and the complex may be narrow or wide.

Stimulants such as cocaine and sympathomimetics produce tachycardia and VF, and opioids cause hypoxic arrest. A toxic arrest may therefore look like any rhythm.

Causal chain

The toxin reaches the heart, vessels, or brainstem. Ion-channel blockade slows conduction or reduces contraction, vasodilation lowers filling and afterload, or apnea removes oxygen. The mechanism determines which antidote can reverse it.

Compressions

Compressions generate flow into a myocardium whose ion channels may still be blocked, so the heart may respond poorly to standard drugs. Prolonged CPR is sometimes considered because the toxin may be cleared or bypassed if the circulation is supported long enough.

Fix

Targeted antidotes reverse specific mechanisms. Sodium bicarbonate raises extracellular sodium and pH, overcoming sodium-channel blockade, and should be used in life-threatening tricyclic cardiotoxicity. Calcium-channel blocker poisoning needs several treatments, not one. In life-threatening poisoning, high-dose insulin and vasopressors should be given for hypotension, calcium is reasonable because it partly overcomes the blockade, and extracorporeal life support is reasonable when the poisoning is refractory to drugs. AHA applies the same therapies to life-threatening poisoning and to cardiac arrest unless it states otherwise, and it does not grade them differently for shock and arrest. The physiological difference still matters: in shock the drugs act on a heart that is still ejecting, while in arrest they act alongside standard resuscitation, which continues. Consider early consultation with a poison center or medical toxicologist. An opioid antagonist reverses opioid receptor effects. Extracorporeal life support can sustain the circulation while a toxin is metabolized.

Bedside

A known ingestion, empty pill bottles, a toxidrome before arrest, or a QRS that was wide before the arrest. Poison center consultation can guide specific antidotes.

Mimics

Hyperkalemia and acidosis widen the QRS. Hypoxia from any cause mimics opioid toxicity.

Limits

Most toxicology recommendations rest on case series and expert opinion. Calcium and bicarbonate are targeted antidotes here, not routine arrest drugs, and the evidence for them during arrest is weaker than their physiological rationale.

Examples

  1. IExample

    Vignette

    A patient who took an overdose of amitriptyline seizes and then arrests. The rhythm before arrest had a very wide QRS.

    Reasoning

    Sodium-channel blockade explains the wide QRS. Sodium bicarbonate should be used for life-threatening tricyclic cardiotoxicity, because raising sodium and pH partly overcomes the blockade.

  2. IIExample

    Vignette

    A patient who took an overdose of extended-release verapamil develops profound bradycardia and hypotension and then arrests.

    Reasoning

    Calcium-channel blockade weakens contraction, dilates vessels, and slows conduction. In life-threatening poisoning, high-dose insulin and vasopressors should be given for hypotension, and calcium is reasonable; AHA does not grade these differently once the heart has arrested. After arrest, standard resuscitation continues alongside them, and extracorporeal support, reasonable when drugs fail, may sustain the circulation while the drug is cleared. Consider early consultation with a poison center or toxicologist.

  3. IIIExample

    Vignette

    A 35-year-old using cocaine develops chest pain and then VF.

    Reasoning

    Cocaine causes coronary vasoconstriction and thrombosis and also lowers the arrhythmia threshold. Both toxin and coronary ischemia may contribute.

Contractility and electrical

Coronary thrombosis4,2

Failure

A clot in a coronary artery cuts off blood to part of the myocardium. Ischemic muscle loses contractility and becomes electrically unstable, so the heart fails as a pump and as a rhythm generator.

Rhythm

Acute coronary occlusion is the classic cause of VF. Later in an ischemic arrest, or with a large infarction, the rhythm may be PEA or asystole.

This cause does not fit the narrow-fast versus wide-slow rule; VF is the expected rhythm, and PEA reflects extensive myocardial failure rather than a filling problem.

Causal chain

A ruptured plaque triggers a thrombus that occludes the artery. The downstream myocardium becomes ischemic within seconds, its electrical properties become heterogeneous, and reentry can trigger VF. If the territory is large, contractility fails and cardiogenic shock follows.

Compressions

Compressions perfuse the non-occluded coronary beds but cannot push blood past the clot. The ischemic territory stays ischemic, so VF may recur after successful shocks.

Fix

Reperfusion, by coronary angiography and intervention, restores blood to the territory. After ROSC, persistent ST elevation with a suspected cardiac cause calls for emergency angiography, and selected patients without ST elevation who have shock, recurrent ventricular arrhythmias, or significant ongoing ischemia are reasonable candidates.

Bedside

Chest pain before arrest, known coronary disease, or VF as the initial rhythm. After ROSC, the 12-lead ECG helps but can overcall ST elevation early and can miss an occlusion.

Mimics

Aortic dissection involving the coronary ostia, cocaine, and coronary vasospasm. Pulmonary embolism can cause chest pain and right heart strain.

Limits

During CPR, coronary occlusion is usually inferred from the history and the rhythm. For adults who arrest in the cardiac intervention laboratory, mechanical CPR devices are reasonable, and extracorporeal life support is reasonable when initial therapy is failing. Those recommendations do not apply to arrest that began before arrival, or to cardiogenic shock without arrest. Early angiography inside extracorporeal CPR trials is not a recommendation to use extracorporeal CPR for coronary thrombosis.

Examples

  1. IExample

    Vignette

    A 58-year-old collapses after an hour of chest pain. VF persists after three shocks.

    Reasoning

    Shock-refractory VF after chest pain suggests ongoing ischemia from an occluded artery. Continued shocks and antiarrhythmics buy time; reperfusion addresses the cause.

  2. IIExample

    Vignette

    After ROSC, the 12-lead ECG ten minutes later shows persistent ST elevation in the anterior leads. The patient remains comatose.

    Reasoning

    Persistent ST elevation with a suspected cardiac cause calls for emergency coronary angiography regardless of coma.

Questions for this part (8)

Question 7.1

Prediction

Predict: the monitor shows a slow organized rhythm, there is no pulse, and the patient has had two doses of epinephrine. What would you expect a third dose to change if the cause is a tamponade?5

Commit to an answer before revealing.

Reveal answer for Question 7.1

Very little. Epinephrine can raise coronary perfusion pressure during compressions, but it cannot relieve a tamponade. While the tamponade persists, the organized rhythm is unlikely to produce a pulse; relieving it is what gives the rhythm a chance to.

Why

In tamponade, pressure in the pericardium stops the heart from filling. Without filling there is little stroke volume, whatever the rhythm or the vascular tone. Removing the pericardial fluid restores filling, and then the organized electrical activity can produce output.

Assumption

Tamponade is actually the cause. The same reasoning applies to hypovolemia, tension pneumothorax, and massive pulmonary embolism, each of which needs its own treatment.

Common misconception

The belief that repeating the drug is the plan. Epinephrine every 3 to 5 minutes and the search for a cause happen together; neither replaces the other.

Question 7.2

Transfer

Transfer: someone asks for calcium and sodium bicarbonate because the arrest has gone on a long time. Using the physiology, what is the default answer, and what would change it?2,3

Commit to an answer before revealing.

Reveal answer for Question 7.2

Do not give either drug just because time has passed. Routine calcium and routine bicarbonate are not recommended, and in arrest suspected from hyperkalemia their benefit is not well established. Specific causes change the answer: calcium for life-threatening calcium-channel blocker poisoning or arrest in a pregnant patient on intravenous magnesium, and bicarbonate for tricyclic or other sodium-channel blocker toxicity.

Why

These drugs treat specific mechanisms, such as calcium-channel blockade or sodium-channel blockade. In undifferentiated arrest the cause is unknown, so the mechanism the drug targets has not been established in this patient. Given routinely across such arrests, trials and registry data have not shown better survival, and routine calcium leans toward harm.

Assumption

The duration of the resuscitation tells you nothing about which mechanism is present. A long resuscitation is a reason to recheck CPR quality and the H and T list.

Common misconception

The belief that a drug which makes physiological sense must help. Hyperkalemia is the clearest example, where the mechanism is plausible but the benefit during arrest is not well established.

Question 7.3

Evidence boundary

Evidence boundary: why is it useful to sort the Hs and Ts by physiology rather than memorize the list, and what can't that sorting tell you?5

Commit to an answer before revealing.

Reveal answer for Question 7.3

Grouping the causes by what fails tells you what kind of treatment each one needs and why compressions alone won't fix it. It cannot tell you which cause is present in this patient.

Why

Causes that empty the heart need volume or decompression, causes that obstruct it need the obstruction removed, and causes that injure the myocardium need the injury reversed. That links each cause to an action.

Assumption

One cause dominates. Arrests often have more than one, and you usually can't confirm them during CPR, so some treatment happens on suspicion.

Common misconception

The belief that a framework is a diagnosis. The grouping guides the search; history, examination, and ultrasound when it doesn't interrupt CPR narrow it.

Question 7.4

Insufficient information

Not enough information: a 70-year-old is found unresponsive at home. The rhythm is a wide, slow PEA at 30 per minute. A team member wants calcium now for hyperkalemia. What data would you need before you could attribute this arrest to hyperkalemia rather than another cause?3,5

Commit to an answer before revealing.

Reveal answer for Question 7.4

Missing data

Kidney function, dialysis schedule, and potassium-raising medications

Any ingestion or access to tricyclics, calcium-channel blockers, or beta blockers

A pre-arrest ECG or EMS rhythm strip

Point-of-care potassium and blood gas, interpreted knowing that acidosis during arrest raises measured potassium

Core temperature

Estimated downtime before CPR

You cannot tell from the rhythm alone. A wide, slow PEA fits hyperkalemia, but it also fits sodium-channel-blocker or calcium-channel-blocker poisoning, severe acidosis, hypothermia, and a long low-flow interval from any cause. The decision depends on history and data you do not yet have.

Why

Several mechanisms slow conduction through the myocardium: a less negative resting potential in hyperkalemia, sodium-channel blockade, acidosis, and cold. Each widens the QRS and slows the rate. Prolonged ischemia from an arrest of any cause does the same, so the rhythm narrows the field without choosing within it.

Assumption

The arrest was unwitnessed, so the downtime, which can produce this rhythm by itself, is unknown.

Common misconception

The belief that a rhythm pattern is a diagnosis. The wide, slow pattern is a category, and calcium's benefit even in suspected hyperkalemic arrest is not well established.

Question 7.5

Prediction

Predict: a hyperkalemic patient with a wide QRS and a weak pulse is given intravenous calcium, and the QRS narrows within minutes. If you drew a potassium five minutes later, what would it show, and what does that imply for the next hour?3

Commit to an answer before revealing.

Reveal answer for Question 7.5

The potassium would be essentially unchanged. Calcium stabilizes the membrane by raising the threshold potential; it does not move or remove potassium. Its effect wears off, so potassium must still be shifted into cells and then removed.

Why

Hyperkalemia makes the resting potential less negative, bringing it close to threshold and inactivating sodium channels. Calcium raises the threshold, restoring the gap between resting and threshold potential, so the cell can again fire a normal action potential. The extracellular potassium concentration is the same before and after.

Assumption

The rhythm improvement was due to calcium and not to another treatment given at the same time.

Common misconception

The belief that a narrowing QRS means the potassium is falling. It means the membrane has been temporarily protected from the potassium.

Question 7.6

Transfer

Transfer: a patient on a high-dose beta blocker develops massive gastrointestinal bleeding and arrests. The PEA is slow, at about 45 per minute, with a narrow complex. Does the slow rate argue against hypovolemia?5

Commit to an answer before revealing.

Reveal answer for Question 7.6

No. The rule that empty-heart states produce fast PEA depends on an intact sympathetic response. Beta blockade blunts the tachycardia, so a hypovolemic arrest can present with a slow rate. The history of bleeding outweighs the rate.

Why

In hypovolemia, falling stroke volume triggers catecholamine release, which speeds the sinus node. A beta blocker blocks that response at the receptor, so the rate stays low even as filling fails. The rhythm then looks less like an empty heart than the physiology really is.

Assumption

The narrow complex reflects intact conduction rather than a toxin or metabolic cause, which supports reading this as a filling problem.

Common misconception

Applying the narrow-fast versus wide-slow rule as a diagnosis. It is a probability shift that depends on intact autonomic responses and a short arrest.

Question 7.7

Insufficient information

Not enough information: after 25 minutes of CPR for an unwitnessed arrest, ultrasound shows a dilated right ventricle. A colleague proposes thrombolysis for pulmonary embolism. What would you need to know before you could attribute the arrest to embolism?3,2

Commit to an answer before revealing.

Reveal answer for Question 7.7

Missing data

Symptoms before collapse, such as sudden dyspnea or pleuritic pain

Risk factors such as recent surgery, immobility, cancer, or known deep vein thrombosis

Whether the right ventricle was dilated on the first view or only after prolonged CPR

Bleeding risk and contraindications to thrombolysis

Availability of catheter or surgical embolectomy or extracorporeal support

A dilated right ventricle after a long arrest is not specific for embolism, because blood pools in the right heart once the circulation stops. You would need history and timing that point to embolism before weighing systemic fibrinolysis, which may be considered when embolism is suspected. It carries a bleeding risk, and the optimal duration of CPR after a fibrinolytic is unclear. That uncertainty is not permission to stop early: the drug needs time to work, and the AHA supportive text notes that the 2019 European Society of Cardiology guideline advises continuing CPR for at least 60 to 90 minutes after a fibrinolytic, a figure based on case reports and case series.

Why

When the heart stops, pressures equalize and the compliant right heart distends with venous blood. Prolonged CPR and right ventricular ischemia add to this. So a late dilated right ventricle can be a consequence of any arrest as well as the signature of an obstructed pulmonary outflow.

Assumption

The ultrasound view is adequate and was obtained without interrupting compressions.

Common misconception

The belief that one ultrasound finding names the cause. During arrest its usefulness is not well established, and the finding has to be weighed against the history.

Question 7.8

Prediction

Predict: a patient in diabetic ketoacidosis arrests with a fast, narrow PEA. The pH is very low and the potassium is high. Someone asks for bicarbonate first. Which failures could be limiting the resuscitation, and what evidence would tell you which matters most?2,5,11

Commit to an answer before revealing.

Reveal answer for Question 7.8

The stem does not establish which failure dominates, and the fast, narrow rhythm cannot decide it. Volume depletion, severe acidemia, and a potassium shift from insulin deficiency and acidosis are all plausible and interact. The discriminating evidence is a potassium and pH on the blood gas, the ECG before and during arrest, and, if an experienced operator can look without interrupting compressions, ventricular filling and the inferior vena cava on ultrasound. Bicarbonate during cardiac arrest is not routinely recommended; its limited place in severe DKA outside arrest is a separate question and is not evidence of benefit during arrest.

Why

Glucose in the urine pulls water and salt with it, and vomiting adds to the loss, so mean systemic filling pressure and venous return fall. Insulin deficiency and metabolic acidosis move potassium out of cells, while osmotic diuresis, vomiting, and hyperaldosteronism deplete total-body stores, so serum potassium can be high while total-body potassium is low. Severe acidemia depresses contractility and vascular tone. Each failure worsens the others: low flow deepens the acidosis, and acidosis blunts the response to the catecholamines that would defend pressure. Later, insulin moves potassium back into cells and can make it fall sharply.

Assumption

That the rhythm carries information here. A narrow complex argues somewhat against severe hyperkalemia as the immediate cause but does not exclude it, and it says nothing about how much volume has been lost.

Common misconception

The belief that one number or one rhythm pattern picks the cause. The pH is the most striking value and the rate is fast, but neither tells you how the failures are weighted in this patient.

Principle

Delivering and adapting treatment

Treatment is delivered in cycles by a team.

What each drug is meant to change, team and system factors, and what to do when the cycle is not working are taken in turn. Each indication's strength sits with its cause in reversible causes.

Principle

What each drug is meant to change2,5,3

Each arrest drug targets one variable.

Asking what that variable is, and whether it is the one limiting the resuscitation, keeps four questions separate: what the drug does, whether it changes the variable, whether that helps the patient, and whether this patient resembles those studied.

Epinephrine. Its alpha-adrenergic effect constricts peripheral arteries, raising relaxation-phase aortic pressure during CPR, which raises coronary perfusion pressure if right atrial pressure does not rise with it. Its beta-adrenergic effects raise myocardial contractility, heart rate, and oxygen demand, which can increase myocardial oxygen consumption in a heart receiving little flow and may favor arrhythmia. The intended target in arrest is the alpha effect. Giving epinephrine is recommended (COR 1, LOE B-R), at 1 mg every 3 to 5 minutes: as soon as feasible in non-shockable rhythms, and after initial defibrillation attempts in shockable rhythms. Neither high-dose epinephrine nor vasopressin as a substitute offers an advantage. The surrogate and the outcome do not move together for this drug: epinephrine increases ROSC and survival to admission, but there is limited evidence that it improves survival to discharge or functional neurological outcome.

Amiodarone and lidocaine. These target the electrical substrate that lets VF restart or persist, not the circulation. Amiodarone blocks several channels and prolongs repolarization; lidocaine blocks sodium channels in depolarized, ischemic tissue. Either may be considered for VF or pulseless VT unresponsive to defibrillation, and the evidence does not distinguish between them. Doses are on the algorithm: amiodarone 300 mg, then 150 mg; lidocaine 1 to 1.5 mg/kg, then 0.5 to 0.75 mg/kg. They are recommended only for VF or pVT unresponsive to defibrillation; there is no fibrillating substrate to treat in PEA or asystole.

Calcium and sodium bicarbonate. Targeted drugs, not general ones: calcium for calcium-channel blockade and selected situations, bicarbonate for sodium-channel blockade. Routine use is not recommended; see the reversible-causes part for each indication and its strength.

Principle

Team and system factors1,12

Many of the variables in this text are controlled by people, not physiology.

Compression quality depends on who is compressing and for how long, so compressor changes are scheduled at rhythm checks rather than left to fatigue. Pauses are shortest when the next action is prepared before the current one ends: the defibrillator charged during compressions, the next compressor ready, the airway operator waiting for a planned pause instead of creating one. A team leader who is not doing a task can watch the clock, the compression fraction, and the reversible-cause list, and can notice when the hypothesis should change. Closed-loop communication is intended to reduce missed or duplicated drugs. After the event, debriefing is how the team learns what the monitor recorded and the room did not see. Debriefing after the event, using the recorded CPR data, is reasonable (COR 2a, LOE B-NR).

Principle

Refractory arrest: recheck, change the hypothesis, escalate1,2,3,12

AHA 2025 gives no fixed definition of refractory arrest; for VF it uses 'persisting VF/pVT' after 3 or more consecutive shocks.

Here the term means the standard cycle is not working. The response has three steps, in order of cost.

First, recheck the basics, because they fail silently. Is compression depth still adequate after compressor changes? Is recoil complete? Is the compression fraction high, or have pauses crept in? Is the tube still in the trachea, and is ventilation slow enough? Are the pads making good contact, in a sensible position, at the right energy?

Second, change the hypothesis. A failing resuscitation is evidence that the working diagnosis may be wrong. Revisit the reversible causes from the history and the course so far: a fast, narrow PEA that never responds may be an obstruction or an empty circulation; recurrent VF may be ongoing ischemia; a wide, slow rhythm may be metabolic or toxic. Treat on suspicion where the guideline supports it, knowing which treatments are recommended, which are of uncertain benefit, and which are not established.

Third, escalate where the system allows. Extracorporeal CPR (ECPR) replaces the failing circulation with a circuit and buys time to treat a cause such as coronary occlusion, pulmonary embolism, hypothermia, or poisoning. Its benefit depends on selection and on a system that can start it quickly; it is not a rescue for every arrest. Rapid intra-arrest transport for ECPR may be considered for limited, highly selected adults with OHCA (COR 2b, LOE B-R), within a system that sets and reassesses selection criteria (COR 2a, LOE C-LD). It is reasonable to rewarm adults in hypothermic cardiac arrest using ECLS (COR 2a, LOE B-NR). Routine mechanical CPR is not recommended (COR 3: No Benefit, LOE B-R); it may be considered where high-quality manual compressions are challenging or dangerous, such as during transport, if interruptions during deployment are strictly limited (COR 2b, LOE C-LD).

Principle

After ROSC

The targets come first, then persistent shock and neurological care.

Principle

After ROSC the goal changes from making flow to limiting a second injury4,7,8

A returning pulse means you are no longer making blood pressure by hand, but it also begins reperfusion of tissue that has been ischemic.

The problem changes. During CPR the aim was to deliver any flow at all. After ROSC the aim is to keep oxygen, carbon dioxide, pressure, and temperature in ranges that limit further injury to a brain and heart that have just been through ischemia. The myocardium is often stunned, vascular tone is abnormal, and the brain may not autoregulate, so values that a healthy patient would tolerate can still cause harm.

The patient can still die of the arrest because the returning pulse ends only the no-flow part of it. Three threats remain, and they run on different clocks. The first is that the circulation fails again: the cause that stopped the heart may still be present, the stunned myocardium may not sustain its output, and a vasodilated circulation may not hold pressure, so shock and re-arrest are the dangers of the first minutes to hours. The second is the brain, which tolerates ischemia among the least of any organ and which, during reperfusion, depends on a pressure gradient it may no longer regulate. The third is every other tissue that was ischemic, where the injury tends to show itself later as organ dysfunction. None of these is undone by the pulse, and each can be made worse by what the team does next.

What is being protected has a location and a mechanism. During arrest, the brain, the myocardium, and every other tissue ran short of oxygen, used up their energy stores, and accumulated the products of anaerobic metabolism. When flow returns, oxygen arrives at cells whose ion pumps, mitochondria, and membranes have been damaged, and the restored supply is thought to generate reactive oxygen species and trigger inflammation in the vessel walls. The result is a second injury that unfolds over hours to days after the pulse returns: in the brain as neuronal death and swelling, in the heart as stunned muscle that contracts weakly even when its arteries are open, and in the circulation as vasodilation and leaky capillaries. Each of the targets below acts on one link in that chain, by limiting how much oxygen, carbon dioxide, pressure, or heat the injured tissue is exposed to.

What you are protecting in the next hour can therefore be stated as four exposures and one search. Oxygen, carbon dioxide, arterial pressure, and temperature are each set by the team, and each acts on one link in the chain just described: oxygen on the supply to reperfused cells and on oxidative injury, carbon dioxide on the tone of the cerebral arterioles, arterial pressure on the gradient into a brain that may follow pressure passively, and temperature on how much oxygen that brain consumes. The search is for the cause, because a cause left in place can stop the heart again however well the four exposures are handled; the 12-lead ECG, the decision about angiography, and imaging belong to that search, and persistent shock and its causes are taken up in the next section. The paragraphs that follow take the exposures in turn, with the ranges the guideline gives and the reasoning behind each.

The 2025 post-cardiac arrest recommendations stay inside ranges that trials have actually compared, and each target guards against a specific way the injured brain and heart can be hurt again. Give 100% oxygen until SpO2 or PaO2 can be measured reliably, because turning the oxygen down before you have a number risks hypoxemia. Once saturation is trustworthy, titrate the inspired oxygen fraction to an SpO2 of 90% to 98% (PaO2 about 60 to 105 mm Hg) and avoid both hypoxemia and hyperoxemia. The two ends fail in different ways: too little oxygen extends the ischemic injury, while too much can add oxidative injury to tissue that has just been reperfused.

The oxygen target is easier to read with the distinction drawn in Part II. SpO2 and PaO2 describe how fully hemoglobin is loaded and the partial pressure of dissolved oxygen, not how much oxygen reaches the tissue, which also depends on hemoglobin and cardiac output. Once hemoglobin is close to fully saturated, a higher PaO2 adds very little content, so hyperoxemia offers almost no gain in delivery while raising the oxygen tension in tissue that is vulnerable to oxidative injury. The target range therefore sits where content is near its maximum and the excess partial pressure is avoided. A patient with severe anemia or low cardiac output can be hypoxic at the tissue level even within the saturation range, so a normal SpO2 is necessary but not sufficient evidence that oxygen delivery is adequate.

In adults who remain comatose after ROSC, keep PaCO2 in a normal physiologic range, generally 35 to 45 mm Hg. Carbon dioxide is one of the strongest controls on cerebral vessel tone, so a low PaCO2 constricts cerebral arterioles and reduces flow to a brain that is already short of it. Mild hypercapnia, the opposite move, did not improve six-month neurologic outcome in the TAME trial.

Carbon dioxide acts on the cerebral vessels from the inside. It diffuses freely from blood into the smooth muscle of the cerebral arterioles, where it changes the local pH; a fall in PaCO2 raises that pH and the arterioles constrict, and a rise lowers it and they dilate. Cerebral blood flow therefore moves with PaCO2 while the vessels can still respond. After arrest, end-tidal CO2 can underestimate PaCO2 by a variable amount, for the dead-space reasons set out in Part VI, so a ventilator adjusted to a normal-looking end-tidal value can leave the arterial value higher or lower than intended. The blood gas, not the capnograph, is the measurement that answers this question.

Avoid hypotension by holding mean arterial pressure at least 65 mm Hg. When autoregulation is impaired, cerebral blood flow follows arterial pressure more directly, so a pressure the healthy brain would tolerate can leave the injured brain underperfused. Randomized comparisons of higher versus lower MAP targets have not shown better survival or neurologic outcome, and aiming below 65 mm Hg has not been shown to be safe in this group.

Arterial pressure matters to the brain through a gradient, like every other flow in this text. Cerebral perfusion pressure in the beating heart is mean arterial pressure minus the pressure opposing inflow, intracranial or venous pressure, whichever is higher. In a healthy brain, autoregulation adjusts arteriolar tone so that flow stays nearly constant across a range of perfusion pressures. After arrest that range may be shifted or lost, so flow follows pressure more passively: a fall in mean arterial pressure lowers flow directly, and swelling that raises intracranial pressure narrows the gradient from the other side. The individual patient's autoregulatory range cannot usually be measured at the bedside, which is why the guideline sets a floor rather than an individual target. Temperature acts on the demand side of the same balance. Cerebral metabolic rate rises with temperature and falls with cooling, so fever increases the oxygen the injured brain needs while its supply is uncertain; the trials compared specific temperature targets, and the guideline recommends keeping temperature within 32 °C to 37.5 °C without naming one value within that range as best.

Record a 12-lead ECG as soon as feasible. An immediate post-ROSC tracing can overcall ST elevation, and the absence of ST elevation does not rule out an intervenable lesion. Persistent ST elevation with a suspected cardiac cause calls for emergency coronary angiography, whether or not the patient is comatose. Without ST elevation, emergency angiography is reasonable for selected patients with a suspected cardiac cause who have cardiogenic shock, recurrent ventricular arrhythmias, or evidence of significant ongoing myocardial ischemia, again regardless of coma. In a comatose patient with none of those features, no ST elevation, shock, electrical instability, or significant ongoing ischemia, emergency angiography is not recommended over a delayed or selective strategy, because randomized trials found no benefit from going early. For adults who remain unresponsive to verbal commands, a deliberate temperature-control strategy is recommended, holding a temperature between 32 °C and 37.5 °C. In that same group, it is reasonable to continue temperature control for at least 36 hours. In adults with spontaneous hypothermia after ROSC, or who are being rewarmed after hypothermic temperature control, it may be reasonable to avoid rewarming faster than 0.5 °C per hour. Routine rapid infusion of cold intravenous fluid for prehospital cooling is not recommended.

Each of these reasons explains why an extreme is harmful; none, by itself, shows that a particular value is best. The targets are population ranges tested against alternatives, and an individual patient may sit at a different point on each curve. Severe anemia, chronic hypertension with a shifted autoregulatory range, raised intracranial pressure, or ongoing shock can all change what a given number means. During care, the practical stance is to meet the guideline ranges while asking, for this patient, what each number does and does not reveal about oxygen delivery, cerebral flow, and the heart.

The limit of the model: these are ranges for a population, and the evidence for several of them is that a different target did not help, not that this exact range is optimal. The reasoning explains why each extreme is dangerous. It does not identify the best value for a particular patient.

After ROSC, protect a vulnerable brainThree domains converge on limiting secondary brain injury: oxygen content, cerebral flow, and metabolic demand. Selected targets are SpO2 90–98% once reliable, PaCO2 generally 35–45 mm Hg in comatose adults, and MAP at least 65 mm Hg. Use 100% inspired oxygen until reliable measurement. RESUS FIRST PRINCIPLES / FIGURE 06 After ROSC, protect a vulnerable brain Section 9.1 • Restored circulation does not end the injury Manage oxygen delivery, perfusion, and metabolic demand together. Oxygen content Hypoxemia reduces oxygen availability. Excess oxygen can add oxidative stress. Cerebral blood flow Hypotension threatens perfusion. Hypocapnia constricts cerebral vessels. Metabolic demand Fever and seizures can increase demand. Injured tissue has limited reserve. Limit secondary brain injury AHA 2025 • SELECTED INITIAL TARGETS Oxygen SpO₂ 90–98% once measurement is reliable. Ventilation PaCO₂ generally 35–45 mm Hg if comatose. Blood pressure Avoid hypotension: MAP at least 65 mm Hg. Use 100% inspired oxygen until oxygenation can be measured reliably. Targets guide initial care; they do not prove adequate tissue perfusion. Physiology overview • Temperature control, EEG/seizure care, cause treatment, and prognosis need separate guidance.

Figure

After ROSC, oxygen availability, cerebral perfusion, and metabolic demand remain interdependent. The displayed oxygen, carbon-dioxide, and blood-pressure targets summarize selected initial AHA 2025 recommendations, not the entire post-arrest care pathway.

Sourceshttps://cpr.heart.org/en/resuscitation-science/cpr-and-ecc-guidelines/post-cardiac-arrest-care

Principle

Persistent shock and finding the cause4

After ROSC the objective changes from making flow to limiting secondary injury, and shock is common.

It is usually multi-mechanism: post-arrest myocardial stunning with low output, vasodilation from systemic inflammation, the original cause if it persists (ischemia, embolism, toxin, hemorrhage), and the effects of drugs given during arrest. The mean arterial pressure floor and the 12-lead ECG are set out in the post-ROSC targets; that target is a floor, not an optimum, and the 2025 guideline removed the previous systolic blood pressure target because the trials used MAP. There is insufficient evidence to recommend a specific vasopressor. Routine temporary mechanical circulatory support should not be used for cardiogenic shock after ROSC, though it may be considered in highly selected patients with refractory shock. Finding the cause matters as much as supporting the pressure: beyond the 12-lead ECG, it may be reasonable to use echocardiography or point-of-care cardiac ultrasound to identify clinically significant diagnoses requiring intervention, and head-to-pelvis CT to investigate the cause of arrest and complications of resuscitation.

Principle

Temperature, seizures, and neurological prognosis4

The brain is the organ most often lost after ROSC, and much of neurological care is about not making it worse and not judging it too early.

Temperature control is set out in the post-ROSC targets. Seizures occur in about 10% to 35% of patients who do not follow commands, and many are visible only on EEG, so EEG should be performed and interpreted promptly in patients who do not follow commands; clinically apparent seizures should be treated, treating nonconvulsive seizures is reasonable, and routine seizure prophylaxis is not recommended. Sedatives and neuromuscular blockers can be cleared slowly after arrest and confound the examination. Prognosis should be multimodal, never based on a single finding, and delayed until enough time has passed to avoid confounding; it is reasonable to consolidate prognostic assessment at a minimum of 72 hours after normothermia and discontinuation of sedatives. The uncertainty to name is specific: a poor early examination may reflect drugs, temperature, or organ failure rather than brain injury.

Questions for this part (3)

Question 9.1

Prediction

Predict: two minutes after ROSC the pulse oximeter has no reliable reading, and someone turns the oxygen down to avoid oxygen toxicity. What is the more likely harm?4,7

Commit to an answer before revealing.

Reveal answer for Question 9.1

Hypoxemia. Until SpO2 or PaO2 is reliably measured, 100% oxygen is recommended. Hyperoxemia is handled by titration once you have a number.

Why

Without a measurement you cannot tell whether the patient is hypoxemic or hyperoxemic. Of the two errors, unrecognized hypoxemia directly extends ischemic injury. The EXACT trial found more hypoxemic events when oxygen was reduced early toward a lower saturation target.

Assumption

The oximeter will soon give a reliable reading, so the period of high oxygen is short.

Common misconception

The belief that a failed oximeter is a reassuring one. You cannot aim for the narrower target until the number exists.

Question 9.2

Transfer

Transfer: after ROSC, a comatose patient's end-tidal CO2 reads 30 mm Hg, and the team wants to slow the ventilator to bring it up to 40. A blood gas has not been drawn. Using what you know about end-tidal CO2, what could go wrong?4,8

Commit to an answer before revealing.

Reveal answer for Question 9.2

End-tidal CO2 after cardiac arrest may be falsely low and may not reflect PaCO2, because poorly perfused lung adds dead space. If the PaCO2 is already normal or high, slowing the ventilator could push it higher. It may be reasonable to obtain a blood gas to assess PaCO2. In this comatose adult, PaCO2 should be kept in a normal range, generally 35 to 45 mm Hg.

Why

End-tidal CO2 approximates PaCO2 only when ventilated lung is well perfused. After arrest, low cardiac output and lung injury create ventilated areas with little blood flow, which dilute the exhaled CO2. The gap between end-tidal and arterial CO2 widens, so the end-tidal value underestimates PaCO2.

Assumption

The gap is large in this patient, which only a blood gas can show.

Common misconception

The belief that end-tidal CO2 and PaCO2 are interchangeable after ROSC. The guideline notes the end-tidal value can be falsely low and supports measuring PaCO2.

Question 9.3

Evidence boundary

Evidence boundary: the MAP floor is 65 mm Hg and trials of higher targets were neutral. Does that mean 65 mm Hg is the ideal pressure for every patient after arrest?4

Commit to an answer before revealing.

Reveal answer for Question 9.3

No. It means aiming higher did not improve outcomes on average, and going lower has not been shown to be safe. It is a floor supported by evidence, not proof of an optimal value for an individual.

Why

An individual patient's autoregulation curve may be shifted, for example by chronic hypertension, so the pressure needed to perfuse their brain can differ from the population average. Neutral trials compare strategies across many patients and can hide that variation.

Assumption

The trial populations resemble the patient in front of you.

Common misconception

The belief that a neutral trial proves the lower target is best. It shows that the higher target did not help on average, which is a different and narrower conclusion.

Principle

Limits and stopping2,3

Stopping is a judgment that further effort is very unlikely to restore a meaningful life, and no single measurement makes it.

Every surrogate available during CPR has failure modes this text has already described: end-tidal CO2 depends on ventilation, tube position, and drugs as well as flow; rhythm says nothing about perfusion; ultrasound findings are operator-dependent and their usefulness during arrest is not established. So the decision is multimodal by construction.

End-tidal CO2 illustrates the rule. In intubated adults, failure to exceed 10 mm Hg after 20 minutes of ALS may be considered as one component of a multimodal decision; in non-intubated adults, a specific end-tidal cutoff should not be used to stop, and doing so is graded as harmful. In hypothermic arrest, end-tidal CO2 is not recommended for predicting outcome.

Context changes the threshold. Patients with environmental hypothermia may survive prolonged arrest neurologically intact, some poisonings can be outlasted with circulatory support, and an arrest with a treatable cause that has not yet been treated is not yet a failed arrest. The questions to answer before stopping are therefore: have the basics been verified, has the cause been sought and treated where possible, is escalation available and appropriate, and do the patient's known wishes and goals fit continuing? Validated prehospital termination rules (BLS, ALS, and Universal TOR rules; COR 1 to 2a, LOE B-NR) are in AHA Part 9 and apply only to adult OHCA; they are not validated for overdose, trauma, or in-hospital arrest. The ethics of the decision is in Part 3.

Cardiac arrest in trauma and in pregnancy is outside the scope of this case. For cardiac arrest in pregnancy, see the 2025 AHA guidance on special circumstances of resuscitation (Part 10); the 2025 AHA guidelines do not include a dedicated section on traumatic cardiac arrest.

Putting it together

Approach to treatment

  1. Start high-quality chest compressions1

    As soon as cardiac arrest is recognized, start compressions right away, on a firm surface when feasible. Use a rate of 100 to 120 per minute, a depth of at least 2 inches (5 cm), and full chest recoil without leaning. Do not treat depths greater than about 6 cm (2.4 inches) as a better compression. Change the compressor about every 2 minutes, or sooner if they are tiring, and make the change at a rhythm check.

    Coronary and cerebral blood flow during arrest are produced by these compressions. The relaxation-phase gradient that perfuses the heart decays as soon as they stop, and it sags when recoil is incomplete or the compressor fatigues. Rotating at the planned 2-minute check keeps depth up without adding a separate pause.

  2. Keep pauses short and shared1

    Limit a pulse check to about 10 seconds, and start compressions if no definite pulse is felt. Without an advanced airway, fold the compressor change and any quick checks into the pause that already exists for the two breaths or a rhythm check. With an advanced airway, breaths continue without pausing compressions, so make the compressor change at a planned rhythm check or shock. Aim for a chest compression fraction of at least 60%, and higher when the team can sustain it.

    An unplanned pause drops coronary perfusion pressure immediately and lowers the fraction of time blood is moving. One short, shared pause usually costs less than several small ones scattered through the cycle.

  3. Defibrillate VF and pulseless VT early2,5

    Attach a monitor-defibrillator as soon as it is available. If the rhythm is VF or pulseless VT, deliver one biphasic shock at the manufacturer's energy, or at the device maximum if that energy is unknown. Use 360 joules if the only device is monophasic. Resume compressions immediately. Prefer this single shock to stacked shocks. On later shocks, use at least the same energy, and consider a higher energy if the device can escalate and there is still no pulse. In witnessed, monitored VF, do not delay the first shock for a drug or an intubation.

    A shock is what terminates VF and pulseless VT, and survival falls as the first shock is delayed. Compressions immediately afterward rebuild the perfusion pressure the shock just interrupted. Epinephrine and airway placement do not replace that first shock.

  4. Oxygenate and ventilate without hyperventilating1,2

    Open the airway and ventilate with a bag-mask and oxygen, using a tidal volume that produces visible chest rise. Without an advanced airway, use 30 compressions and 2 breaths. If an advanced airway is in place, give 1 breath every 6 seconds (10 per minute) and do not pause compressions for the breath. Defer advanced-airway placement when it would interrupt compressions, until initial CPR and defibrillation have failed or ROSC has occurred. Confirm an endotracheal tube with continuous waveform capnography and clinical assessment. If end-tidal CO2 is low or falling, reassess CPR quality and tube position before you reassess prognosis.

    Blood moved by compressions still has to carry oxygen, but excessive ventilation can decrease cardiac output: extra breaths raise intrathoracic pressure and can reduce venous return, which tends to lower the coronary gradient those compressions created. Airway insertion and a long look at the capnograph are interruptions unless they stay off the early CPR and defibrillation path.

  5. Give epinephrine on a rhythm-specific clock2

    Attempt intravenous access first, without stopping compressions. Use intraosseous access only if intravenous attempts fail, are not feasible, or are delayed. Give epinephrine 1 mg every 3 to 5 minutes by whichever route is obtained. In asystole or PEA, give the first dose as soon as feasible. In VF or pulseless VT, give it after initial defibrillation attempts have failed, not before the first shock. Do not use high-dose epinephrine. Vasopressin, alone or combined with epinephrine, offers no advantage as a substitute.

    Epinephrine's alpha effect raises relaxation-phase aortic pressure and can therefore raise the coronary perfusion pressure compressions are generating. In a shockable rhythm that dose waits until shocks have been tried, because the rhythm itself is the problem defibrillation treats. Placing the line and giving the drug must not create an extra pause.

  6. Add an antiarrhythmic only for shock-refractory VF or pulseless VT2,3

    If VF or pulseless VT continues after defibrillation, amiodarone or lidocaine may be considered. Amiodarone is 300 mg IV or IO, then 150 mg if a second dose is needed. Lidocaine is 1 to 1.5 mg/kg IV or IO, then 0.5 to 0.75 mg/kg. Do not give calcium or sodium bicarbonate as routine arrest drugs.

    These antiarrhythmics are an adjunct for a shockable rhythm that defibrillation has not settled. They are not treatment for PEA or asystole, and they do not replace further shocks or CPR. Routine calcium and bicarbonate, given without a specific indication, have not improved outcomes, and their benefit in arrest suspected from hyperkalemia is not well established. Calcium is reasonable for life-threatening calcium-channel blocker poisoning and for arrest in a pregnant patient receiving intravenous magnesium. Sodium bicarbonate should be used for life-threatening tricyclic antidepressant cardiotoxicity, and it is reasonable for life-threatening cardiotoxicity from sodium-channel blockers other than tricyclic and tetracyclic antidepressants.

  7. Search for Hs and Ts while CPR continues5,2

    During compressions, look for hypovolemia, hypoxia, acidosis, hypo- or hyperkalemia, hypothermia, tension pneumothorax, cardiac tamponade, toxins, pulmonary thrombosis, and coronary thrombosis, and treat the cause you find. Ultrasound's usefulness during arrest is not well established; use it only if an experienced operator can do it without stopping compressions.

    A mechanical or metabolic cause is unlikely to resolve with compressions and epinephrine alone. The search is part of resuscitation, but it is not a reason to let coronary perfusion pressure fall to zero while people look.

  8. Limit secondary injury after ROSC4

    When a pulse returns, leave 100% oxygen on until SpO2 or PaO2 is reliably measured, then titrate to an SpO2 of 90% to 98%. In a patient who remains comatose, ventilate toward a PaCO2 of about 35 to 45 mm Hg. Correct hypotension so mean arterial pressure is at least 65 mm Hg. Record a 12-lead ECG as soon as feasible. If the patient does not respond to verbal commands, control temperature between 32 °C and 37.5 °C, and it is reasonable to continue that control for at least 36 hours. In adults with spontaneous hypothermia after ROSC, or who are being rewarmed after hypothermic temperature control, it may be reasonable to avoid rewarming faster than 0.5 °C per hour. Do not give a routine prehospital bolus of cold intravenous fluid to force hypothermia.

    After ROSC the problem changes from no flow to reperfusion. Hypoxemia, hyperoxemia, hypocapnia, hypotension, and uncontrolled temperature can each add injury to a brain that may not be autoregulating. These are the ranges and floors from the 2025 post-cardiac arrest guideline, including the shift from the ventilation limits used during CPR to a normal PaCO2 once a pulse has returned.

References

  1. 2025 American Heart Association Guidelines for CPR and ECC, Part 7: Adult Basic Life Support
  2. 2025 American Heart Association Guidelines for CPR and ECC, Part 9: Adult Advanced Life Support
  3. 2025 American Heart Association Guidelines for CPR and ECC, Part 10: Adult and Pediatric Special Circumstances of Resuscitation
  4. 2025 American Heart Association Guidelines for CPR and ECC, Part 11: Post-Cardiac Arrest Care
  5. 2025 AHA Adult Cardiac Arrest Algorithm
  6. Stieglis et al. Time to defibrillation and VF termination and survival (ARREST registry). Circulation 2025;151:235-244 First-shock VF termination and the relative reduction in survival per minute of delay.
  7. Bernard et al. Effect of lower vs higher oxygen saturation targets on survival after out-of-hospital cardiac arrest (EXACT). JAMA 2022
  8. Eastwood et al. Mild hypercapnia or normocapnia after out-of-hospital cardiac arrest (TAME). N Engl J Med 2023
  9. Yannopoulos et al. Effects of incomplete chest wall decompression during CPR on coronary and cerebral perfusion pressures. Resuscitation 2005;64:363-372
  10. Jellinek et al. Influence of positive airway pressure on the pressure gradient for venous return in humans. J Appl Physiol 2000;88:926-932 Ten anesthetized adults: mean systemic filling pressure, right atrial pressure, and left ventricular stroke volume at 0 and 15 cmH2O airway pressure during apnea.
  11. Umpierrez et al. Hyperglycemic crises in adults with diabetes: a consensus report. Diabetes Care 2024 Potassium shifts and the limited place of bicarbonate in severe DKA, outside cardiac arrest.
  12. 2025 American Heart Association Guidelines for CPR and ECC, Part 4: Systems of Care (Dezfulian C, et al. Circulation. 2025;152(suppl 2):S353–S384)
  13. Paradis NA, Martin GB, Rivers EP, et al. Coronary perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitation. JAMA. 1990;263(8):1106–1113
  14. Aufderheide TP, Sigurdsson G, Pirrallo RG, et al. Hyperventilation-induced hypotension during cardiopulmonary resuscitation. Circulation. 2004;109(16):1960–1965
  15. Repessé X, Charron C, Fink J, et al. Value and determinants of the mean systemic filling pressure in critically ill patients. Am J Physiol Heart Circ Physiol. 2015;309(5):H1003–H1007
  16. Takata M, Wise RA, Robotham JL. Effects of abdominal pressure on venous return: abdominal vascular zone conditions. J Appl Physiol. 1990;69(6):1961–1972
  17. Persichini R, Silva S, Teboul JL, et al. Effects of norepinephrine on mean systemic pressure and venous return in human septic shock. Crit Care Med. 2012;40(12):3146–3153
  18. Maas JJ, Pinsky MR, de Wilde RB, et al. Cardiac output response to norepinephrine in postoperative cardiac surgery patients: interpretation with venous return and cardiac function curves. Crit Care Med. 2013;41(1):143–150
  19. Rudikoff MT, Maughan WL, Effron M, Freund P, Weisfeldt ML. Mechanisms of blood flow during cardiopulmonary resuscitation. Circulation. 1980;61(2):345–352
  20. Werner JA, Greene HL, Janko CL, Cobb LA. Visualization of cardiac valve motion in man during external chest compression using two-dimensional echocardiography. Circulation. 1981;63(6):1417–1421
  21. Fisher J, Vaghaiwalla F, Tsitlik J, et al. Determinants and clinical significance of jugular venous valve competence. Circulation. 1982;65(1):188–196
  22. Higano ST, Oh JK, Ewy GA, Seward JB. The mechanism of blood flow during closed chest cardiac massage in humans: transesophageal echocardiographic observations. Mayo Clin Proc. 1990;65(11):1432–1440
  23. Porter TR, Ornato JP, Guard CS, et al. Transesophageal echocardiography to assess mitral valve function and flow during cardiopulmonary resuscitation. Am J Cardiol. 1992;70(11):1056–1060
  24. Redberg RF, Tucker KJ, Cohen TJ, et al. Physiology of blood flow during cardiopulmonary resuscitation. A transesophageal echocardiographic study. Circulation. 1993;88(2):534–542
  25. Cain SM. Oxygen delivery and uptake in dogs during anemic and hypoxic hypoxia. J Appl Physiol. 1977;42(2):228–234
  26. Ronco JJ, Fenwick JC, Tweeddale MG, et al. Identification of the critical oxygen delivery for anaerobic metabolism in critically ill septic and nonseptic humans. JAMA. 1993;270(14):1724–1730
  27. Roh YI, Kim HI, Kim SJ, et al. End-tidal carbon dioxide after sodium bicarbonate infusion during mechanical ventilation or ongoing cardiopulmonary resuscitation. Am J Emerg Med. 2024;76:211–216
  28. Okamoto H, Hoka S, Kawasaki T, Okuyama T, Takahashi S. Changes in end-tidal carbon dioxide tension following sodium bicarbonate administration: correlation with cardiac output and haemoglobin concentration. Acta Anaesthesiol Scand. 1995;39(1):79–84
  29. Cantineau JP, Merckx P, Lambert Y, et al. Effect of epinephrine on end-tidal carbon dioxide pressure during prehospital cardiopulmonary resuscitation. Am J Emerg Med. 1994;12(3):267–270
  30. Gudipati CV, Weil MH, Bisera J, Deshmukh HG, Rackow EC. Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation. Circulation. 1988;77(1):234–239
  31. Falk JL, Rackow EC, Weil MH. End-tidal carbon dioxide concentration during cardiopulmonary resuscitation. N Engl J Med. 1988;318(10):607–611
  32. Zipes DP, Fischer J, King RM, Nicoll AdeB, Jolly WW. Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardium. Am J Cardiol. 1975;36(1):37–44
  33. Paradis NA, Martin GB, Goetting MG, et al. Aortic pressure during human cardiac arrest. Identification of pseudo-electromechanical dissociation. Chest. 1992;101(1):123–128
  34. Bocka JJ, Overton DT, Hauser A. Electromechanical dissociation in human beings: an echocardiographic evaluation. Ann Emerg Med. 1988;17(5):450–452